MICON 500C Electronic Sequencing
41
234AY00.INS R06
Computer Installation Guide
DISPLAY
CODE
DESCRIPTION OF
FAULT
PROBABLE CAUSE
RECOMMENDED ACTION
TO CLEAR FAULT
CONDITION
CO26
PULSER FAULT
Missing or disconnected pulser.
Check customer harness lead
electrical connections (see
section 4.2 – American, pp 11-
12; section 4.3 - European, pp
13-14)
1. Correct source of error.
2. Turn handle switch OFF,
then ON.
CO27
PULSER BUFFER
OVERFLOW FAULT
Input pulses coming in faster
than MICON 500C rated to
handle.
Micro motion meter may be
programmed for higher
ppu
than
MICON 500C rating.
Ensure micro motion meter and
MICON 500C flow rates are
compatible.
1. Correct source of error.
2. Turn handle switch OFF,
then ON.
CO28
DISPLAY DISCONNECT
FAULT
LCD lost connection.
Check connections. If
connections are valid, display
may require replacement.
1. Correct source of error.
2. Turn handle switch OFF,
then ON.
CO29
EEPROM CHECKSUM
FAULT
EEPROM corrupted.
Reset pumphead by turning
handle switch OFF, then ON.
If reset ineffective, reprogram
the MICON, using the INFO-
PAC.
If reset and reprogramming
ineffective, internal processor
may require replacing. Contact
your service representative.
1. Correct source of error.
2. Turn handle switch OFF,
then ON.
CO30
EXCESSIVE REVERSE
COUNTS
Pulser connected backwards.
Reconnect pulser (see section
4.2 – American, pp 11-12;
section 4.3 - European, pp 13-
14)
1. Correct source of error.
2. Turn handle switch OFF,
then ON.
CO51
EXCESS FLOW FAULT
Flow rate has exceeded INFO-
PAC maximum setting OR
hose ruptured.
Check for hose ruptures. If no
leaks are occurring, it may be
necessary to adjust INFO-PAC
EXCESS FLOW setting (see
section 8.6, page 36).
Ø
Turn handle switch OFF,
then ON—
OR--
Ø
activate MRST input
and/or push button on
main board
CO76
PRESSURE
TRANSDUCER 1 OUT
OF RANGE
Pressure transducer 1 input is
less than or greater than 4 mA
to 20 mA acceptable range.
Check transducer
connections / performance.
Activate MRST input and/or
push button on main board.
CO77
PRESSURE
TRANSDUCER 2
OUT OF RANGE
Pressure transducer 2 input is
less than or greater than 4 mA
to 20 mA acceptable range.
Check transducer
connections / performance.
Activate MRST input and/or
push button on main board.
CO78
AMBIENT
TEMPERATURE PROBE
FAULT
Probe has short circuit or open
circuit.
Check probe connections /
replace probe.
Activate MRST input and/or
push button on main board.
CO79
GAS TEMPERATURE
TRANSDUCER OUT OF
RANGE
Gas temperature transducer
input is less than or greater than
-50
°
C to +50
°
C acceptable
range.
Check transducer
connections / performance.
Activate MRST input and/or
push button on main board.
CO80
PRESSURE
TRANSDUCERS 1 AND
2 OUT OF TOLERANCE
Pressure transducers PXT1 and
PTX2 (back-up) have exceeded
a 3% difference in readings.
Check transducer
connections / performance.
Activate MRST input and/or
push button on main board.
CO81
AIR PURGE OR
PRESSURE SWITCH
KILL
Purging is not occurring, due to
open circuit at switch. (This
switch input may be used for
applications other than air
purge.)
Qualified personnel may check
for open circuit and repair
switch.
Activate MRST input and/or
push button on main board.
CO82
EXCESS FILL FAULT
Flow rate has exceeded INFO-
PAC maximum setting OR
hose ruptured.
Check for hose ruptures. If no
leaks are occurring, it may be
necessary to adjust INFO-PAC
EXCESS FILL setting (see
section 8.6, page 36).
Activate MRST input and/or
push button on main board.
TABLE 13 – MICON 500C FAULT CODES