MICON 500C Electronic Sequencing
19
234AY00.INS R06
Computer Installation Guide
FIGURE 15
PRICE SETTING
USING THE MICON
COMMUNICATOR
6.2.2 SETTING PRICES ON A SINGLE TIER DISPENSER
(SINGLE TIER: FOR TWO TIER PRICE SETTING, GO TO PAGE 22.)
1. Go to breaker box and turn OFF AC power to MICON 500C electronic pumphead being
serviced.
Caution: Ensure breaker box does not feed power to equipment which
should remain ON.
MICON display should be flashing.
If display is not flashing, unit is in
sleep
mode. To correct this, turn handle ON and OFF.
Display will start flashing. The dollar (top) display on the MICON 500C displays the dollar
amount and “Prc 1”.
2. Take the MICON hand held communicator and go to the front display of the MICON 500C
electronic pumphead.
3. Aim the communicator at the optical sensor (oval hole ) at right of price display on
MICON 500C.
4. To set prices:
§
While aiming the communicator’s transmitter (located on the end of the unit) at the
MICON 500C optical display sensor, press and hold the “SET” key until the display
increments to the desired number.
§
Use the “SEL” key to select the next digit to be changed. Press and hold the “SET” key
until the display increments to the desired number.
§
When the correct price per unit has been entered, restore head power while handle
switch remains in the OFF position.
MICON hand held
communicator
MICON 500C
electronic
pumphead display
Aim end of
communicator
at optical
sensor