MICON 500C Electronic Sequencing
25
234AY00.INS R06
Computer Installation Guide
7.0
MICON 500C SEQUENCING
The INFO-PAC settings relevant to switching between low, mid and high banks are shaded in
Table 6 and Table 7 (below and next page). They are m500 – MIN. FLOW, MAX FLOW; m500c – FILL
OPTION, IPTP FLOW 1, IPTP FLOW 2; defined on pages 26, 27.
OPTION
DESCRIPTION
DEFAULT
SETTINGS
SETUP MODE m500
CONFIG
sets menu options to custom or default configurations
default
TEST
sets test mode ON or OFF
off
PULSER
selects pulser input source: I.S. circuit external wiring or conduit wiring
.i.s.
IN COUNT
indicates number of quadrature (input pulser) transitions per unit
displayed
1000
MULTIPLIER
factor used to adjust pulser edges per unit of product (works with IN
COUNT)
1
CURRENCY
selects monetary unit for currency display
dollars
VOL DISP
sets number of decimal places in the volume unit display
1.000
SUPPRESS
sets number, if any, of units of flow suppression at beginning of
transaction
0.030
CONV.
metric – Imperial – US volume conversion; not for CNG applications
off
PRC RESTORE
automatically restores tier 1 price after tier 2 is used
on
NO FLOW
sets
no flow
(sale in progress but no product flow registering) timer ON
off
VOL P. QUAD
sets volume out pulser as single channel, with penny pulser option; or
two channel quadrature pulser output with penny pulser disabled
off
VOL PPU
sets number of output pulses per unit
10
VOL PW
sets pulse width of output signal
4.0ms
PENNY PW
sets pulse width of penny pulse signal
4.0ms
W/M STANDARD
sets allowable pulser errors to N. American or European standards
na
CLEAR ZEROS
permits display or suppression of leading zeros in current sale
off
CONSOLE
shows type of communications protocol used (Kraus, Tokheim,
Gilbarco)
kraus
PUMP ID.
sets pump address used for serial data communication
not set
GRADE
features vary according to interface manufacturer (Kraus, Tokheim,
Gilbarco)
1
DISPLAY
sets current sale display interpretation; use default setting for CNG
applications
normal
MASS CONV.
indicates mass of fuel sold in gasoline gallon or gasoline litre
equivalents
off
HOSE SIZE
sets size of CNG dispensing hose
0.00
TURBINE
permits turbine meter option
disab
T. CALIB
sets turbine meter calibration values
10000
T. UNITS
sets final calculated units for turbine meters
1b
MIN. FLOW
flow rate used to determine whether sale is completed
00.4
MAX FLOW
excess fill threshold above which Micon 500C will end the filling
transaction
030
SLOW FLOW
sets (for preset sales) when fast flow valve closes; slow flow valve only
remains
0.600
START KEY
reserved for future expansion; set to default (disab) only
disab
STOP KEY
reserved for future expansion; set to default (disab) only
disab
CUST. PRESET
reserved for future expansion; set to default (disab) only
disab
P. CODE
sets personal security code for price changing
0000
TRANSMIT
transmits pump configuration info to Micon 500 head
off
RX MICON
receives Micon 500C settings from units already programmed
off
TABLE 6 – M500 INFO-PAC PROGRAMMABLE FEATURES (FOR CNG); SOFTWARE VERSION 3.0