Step 12: Install the lamp key into the controller (LTW-5 systems only). The key always comes
packaged with the lamp and sits on the connector. With the key removed from the lamp, orient
it so the label is upright and facing you. The key will plug into the lamp key port on the right side
of the controller (Figure 9).
Step 13: Plug the lamp connector into the lamp. Note the keying for proper alignment (see Fig-
ure 8a, 8b). Insert the lamp connector into the gland nut and turn the connector approximately
¼ turn to lock the connector to the gland nut as in Figure 10.
Figure 9. Lamp Key Installation
Figure 10. Connector
Step 14: Tighten the captive ground screw to the ground lug on the UV reactor to ensure proper
grounding.
Figure 11. Ground Screw Connection
Step 15: Your system is now ready to be plugged into the appropriate GFCI protected outlet.
Refer to the following section before any water is allowed to flow through the system.
Note: Installation of your disinfection systems shall comply with
applicable provincial/state & local regulations.