The  Gill  2  Seating  System  is  the  result  of  experienced,  thoughtful  design  and 
rigorous testing over 12 months of in-house testing and frontal impact testing.  
 
The  Gill  2  was  successfully  tested  to 
ISO  16840-4  at  the  Transport 
Research  Laboratory  in  May  2013, 
using  the  HIII  5th  Percentile  Test 
Dummy to 49Kg. 
 
However, this does not imply and is not 
intended  to  imply  in  any  way,  that  the 
GILL  2  Seating  System  is  suitable  for 
transporting  an  occupant  in  a  motor 
vehicle  in  any  other  way  than  with  the 
GILL 2 Seating System being correctly    
interfaced  with  a  surrogate  wheelchair 
of a type and model  which has  been successfully tested  in its own right, to meet 
the  requirements  of  ISO  7176-19  (Wheeled  mobility  devices  for  use  in  Motor 
Vehicles). 

 

The transporting vehicle 

MUST

 be suitably equipped with wheelchair and  

     occupant restraint systems compliant with ISO 10542. 

     

Under No Circumstances 

should any part of a transportation restraint         

     system, be attached directly to the GILL 2 Seating System. 

 

ALWAYS

 check both backrest retaining strap buckles (Fig.4) are connected & 

tensioned sufficiently prior to using the GILL 2 on transportation. 

 

Whilst provision is made on the GILL 2 Backrest for attachment of an ancillary 
Postural  Positioning  Harness,  which,  if  fitted,  should  still  be  utilised  as  normal 
during  any  transportation  period,  this  positioning  device  should 

NEVER

  be 

used as the sole method of occupant restraint during transportation. 

The restraint systems used for the surrogate  wheelbase and occupant during the 
above testing, are manufactured by:-  

Unwin Safety Systems. 

C.N. Unwin Ltd., Unwin House, The Horseshoe, Coat Road, Martock, Somerset, TA12 6EY. 

Tel: 01935 827740  

Fax: 01935 827760 

Email: [email protected] 

Web: www.unwin-safety.com   

Part numbers:- 

  

Wheelbase restraints: Front

—OF03  Rear—OR02 

Occupant restraints: Static 3PT 
These  kits  meet  the  requirements  of  ISO  10542,  (Wheelchair  Tie-downs  and 
Occupant Restraint Systems). 
If the intended transporting vehicle is not already fitted with Unwin type anchorage 
tracks, details of these can also be obtained direct from Unwin Safety Systems Ltd 

NOTE: 

Installation and use of all restraint systems should always be strictly as per 

their manufacturers recommendations.

 

Содержание Gill 2

Страница 1: ...Installation and User Manual For use with the Invacare Action Range of Wheelchairs July 2014 Edition 2 Seating System 2 ...

Страница 2: ...Seating Systems ...

Страница 3: ...houghtful design and rigorous in house testing field trials and frontal impact testing over 12 months Many adjustable features have been built into the Gill 2 enabling it to become an extremely versatile seating system available in four sizes RMS Ltd reserves the right to change without notice the design methods of manufacture or raw materials used in the construction of the Gill 2 Seating System ...

Страница 4: ...able Pelvic Supports Further compatible accessories are available from the RMS Product and Accessory Catalogue Technical Information Gill 2 Seating System Size Guide Size 1 Gill2 1 01 00 Size 2 Gill2 2 01 00 Size 3 Gill2 3 01 00 Size 4 Gill2 4 01 00 Pelvic Width Min Max 200mm 275mm 250mm 325mm 315mm 375mm 365mm 425mm Seat Depth Min Max 225mm 300mm 300mm 375mm 360mm 435mm 430mm 505mm Backrest Heigh...

Страница 5: ...affect their original pre set position To accommodate any changes in user growth or postural positioning it is recommended that the user be checked at regular intervals by a suitably qualified person to ensure that adjustable components are correctly set to suit the user s current requirements Carers should ensure correct utilisation of any positioning Straps or Harnesses as failure to do so could...

Страница 6: ...S check both backrest retaining strap buckles Fig 4 are connected tensioned sufficiently prior to using the GILL 2 on transportation Whilst provision is made on the GILL 2 Backrest for attachment of an ancillary Postural Positioning Harness which if fitted should still be utilised as normal during any transportation period this positioning device should NEVER be used as the sole method of occupant...

Страница 7: ...s with Pull tight Buckles RMS Padded Single pull Pelvic Belt PB009 sizes 1 2 PB007 sizes 3 4 Height and width adjustable positive locking swing away Thoracic Supports with removable machine washable covers 7 Extended Backrest Cushion to allow for use of Back Extension Interface Seat Hook Brackets with pre drilled alternative mounting positions Hayden Clamps installed onto Seat Rails to locate Seat...

Страница 8: ...d Seat canvasses from the surrogate wheelchair This is done by disconnecting and removing the Backrest Tubes from the wheelchair and sliding the Canvas downwards off the Tubes Refit and secure both Backrest Tubes 2 The Seat Canvas can be removed by carefully prizing out the black blanking plugs from each end of the Seat Rails and save for re use Remove the locking grub screws 4 located on the unde...

Страница 9: ...sufficient to lift the Seat Unit clear of the wheelchair At this stage make any minor adjustments to the Clamp positions before fully securing the Clamps sufficient to prevent any movement CAUTION Ensure the Clamp securing nuts do not foul the Parking Brake Mounts or front Seat Rail Saddles when tightening adjust the Clamp or Hook Bracket positions accordingly if necessary before fully securing 10...

Страница 10: ... the Seat Unit the wheelchair should open out to enable all four Seat Hook Brackets to fully engage over each wheelchair Seat Rail with both front Hook Brackets engaging between their Locating Clamps 5 With the Seat Unit now in place on the Seat Rails route the Backrest Retaining Straps outwards in front of the Backrest Tubes then around the outside of the Tubes finally to be connected centrally b...

Страница 11: ...nel when set to maximum length BACKREST HEIGHT ADJUSTMENT From the standard position the Backrest height is adjustable upwards by 75mm Tools Required 4mm Hexagon Key To adjust Backrest Height 1 Remove the Velcro attached Backrest Cushion 2 Using the 4mm Hexagon Key slacken the M6 Hex Head Screws securing the Backrest Extension Panel Fig 6a 3 Slide Backrest Height Adjustment Panel upwards to the re...

Страница 12: ...9 9 2 Note or mark current positions of Front Seat Hook Bracket Locating Clamps 3 Slacken clamping nuts sufficient to be able to slide all Clamps forwards equally on the Seat Rails by 25mm for 5º increase in Backrest angle or 50mm for 10º increase 4 Ensure both rear Locating Clamps are set at equal distance from the front of each Seat Rail and retighten Clamps sufficient to prevent any movement Po...

Страница 13: ...ront Seat Hook Bracket and relocate to either one or two holes rearwards on the Seat Panel see page 7 NOTE Moving the Hook Brackets rearwards by one hole will change the Backrest angle to 95º whereas moving two holes will achieve the 100º angle Fig 7a 4 Ensure both Hook Brackets are level across the Seat and retighten the domed securing nuts sufficient to prevent any movement 5 Re install Seat Dep...

Страница 14: ...ards or outwards to the required position 2 Re secure Pelvic Supports by retightening the M6 domed Nylock Nuts THORACIC SUPPORT ADJUSTMENTS The Thoracic Supports are of the positive locking swing away style currently being successfully used on other RMS Gill Seating Systems such as the Gill 3 Junior Gill 3 and the Gill 4 To enable the Supports to swing away during user transfers depress the green ...

Страница 15: ...face of the Backrest Panel insert each retaining screw through the appropriate hole in the Backrest Panel and screw into the key washers ensuring that the key washers are correctly located in the Thoracic Support Mounting Brackets DO NOT FULLY TIGHTEN at this stage 5 Repeat the above for the opposite side Adjust Thoracic Pad Width as detailed below To adjust Thoracic Pad Width NOTE It will not be ...

Страница 16: ...ustable Stem has two pivot points both of which should be slackened to enable the Headrest to be moved in a forward or rearward direction Fully tighten both M8 nuts sufficient to prevent any movement The overall height of the Headrest and Stem assembly is locked off by the Black Thumb Screw located on the Stem Mount attached to the Backrest To enable the Headrest to be refitted to the same height ...

Страница 17: ...oved with a clean damp cloth Water Based Stains can be cleaned using mild liquid detergent with warm water Cold water should be use for stains produced by bodily fluids then rinsed Thoroughly Followed by drying with a clean absorbent cloth Light Steam Cleaning can be carried out in situ ensure all areas are completely dry before reuse Machine Washing with care 40 Covers must NOT be turned inside o...

Страница 18: ...yond its control Therefore items such as Upholstery may only be considered for repair or replacement under the terms of the product warranty where a failure is clearly attributed to a manufacturing or material defect With the exception of modifications and or alterations carried out by the manufacturer to meet the clinical needs of the user any attempt to change the design or modify the constructi...

Страница 19: ...19 GENERAL INFORMATION RECORD Your GILL 2 Seating System Serial Number is Wheelchair Model and Serial Number Date of Supply Supplied to NOTES ...

Страница 20: ...Seating Systems Manufactured By THOMPSON HOUSE Unit 10 Styles Close Sittingbourne Kent ME10 3BF Tel 01795 477280 Fax 01795 229692 E mail sales rms kent co uk Web www ineedawheelchair co uk ...