General Specifications 

Transmission method

Frequency modulated light via two optical fibers

Multimode:

1310nm

Single-mode: 

1310/1550nm

Maximum Fiber Loss / 

Distance*

Multimode:      

1.25 mi. / 2km range

Single-mode:     12.4 mi. / 20km range

37 mi. / 60km range

74 mi. / 120km range

Single Fiber, Bi-directional

Single-mode:     12.4 mi. / 20km range

37 mi. / 60km range

*Note

: Distances equated using industry standard fiber and connector attenuation.

(Multimode: 3.5dB/km, Single-mode: 0.4db/km, + 0.5dB per connector, + 0.3dB per splice)

Fiber Type

Multimode: 62.5/125µm, 50/125µm

Single-mode: 9/125µm

Fiber Connector Types

ST or SC 

Analog Bandwidth

300Hz to 3400Hz

Channel Noise

< 20dBrnC (15dBrnC typical)

Nominal Impedance

600 Ohm input and output

Insertion Loss

0dB +/- 0.5dB each direction

Overload Level

8dBm into 600 Ohms

E&M Input

24-48VDC, 3000Vrms optically isolated

E&M Output

1500VRMS isolation by normally open solid state relay: 

Closed resistance 35 Ohms (220VAC or 330VDC @ 150mA max.) Open resistance >1M Ohms

Response Time 

Input to output 15-18ms.

Surge Protection

PTC thermistors varistors

Bi-Directional

Contact Closure (I/O)

Inputs

Dry contact (100 Ohms maximum loop impedance)

Outputs

Relay - Normally Open

Relay Max. Rating

125VAC / 0.5A / 62.5VA

30VDC / 2.0A / 60 Watts

Power Requirements

24-56VDC

Power Consumption

6 Watts Maximum

Operating Temperature

-40° to +158° F (-40° to +70° C), 95% non-condensing

Dimensions

H 4.93” x W 1.20” x D 3.93” (not including DIN clip)

Warranty

Limited Lifetime

 

Visit 

www.fiberopticlink.com

 for warranty details

 

RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

 

Page 

"

9

Содержание 2 Channel 4 Wire Data with E&M and I/O

Страница 1: ...and made in the U S A and covered by our Limited Lifetime Warranty Key Features Hardened to operate in 40 F to 158 F 40 C to 70 C System power options 24 48VDC and 125 VDC Multimode or single mode fi...

Страница 2: ...ng connections to this device Guidelines for handling terminated fiber cable Do not bend fiber cable sharply Use gradual and smooth bends to avoid damaging glass fiber Keep dust caps on fiber optic co...

Страница 3: ...y using fiber optic cable the DIN Fiber Link system provides absolute electrical isolation Application Diagrams The diagram below shows a typical configuration of the 4 Wire Data with E M and I O syst...

Страница 4: ...VDC or 125VDC depending on model Flat head screwdriver for connection wiring Phillips screwdriver for attaching to wall optional Physical layout POWER FIBER FIBER LINK INPUT OUTPUT INPUT OUTPUT I O 1...

Страница 5: ...put signal and RX is the input signal Single fiber models combine input and output signals over one fiber strand Connect fiber cables to the correct TX and RX ports On dual fiber models the TX port of...

Страница 6: ...us LED s located on the upper and lower ends of the RJ 45 Socket The upper LED is ON when the input is active and OFF when no input is present The lower LED is ON when the E M output is closed and OFF...

Страница 7: ...load wiring prior to installation or maintenance Connect power The system accepts a 24 48VDC or 125VDC local power source depending on the model The power inputs are identified on the top of the devic...

Страница 8: ...tatus Description POWER Power ON System Power OK FIBER Fiber Optic Link ON Fiber Link is Connected OFF Fiber Link is Disconnected INPUT Input Sensor ON Input On Active OFF Input Off OUTPUT Output Rela...

Страница 9: ...input and output Insertion Loss 0dB 0 5dB each direction Overload Level 8dBm into 600 Ohms E M Input 24 48VDC 3000Vrms optically isolated E M Output 1500VRMS isolation by normally open solid state re...

Страница 10: ...20km 12 4 mi 8 9 m A 4D 2EM IO 10 1 B 4D 2EM IO 11 1 60km 37 mi 8 9 m A 4D 2EM IO 14 1 B 4D 2EM IO 15 1 Single mode SC 20km 12 4 mi 8 9 m 4D 2EM IO 40 1 60km 37 mi 8 9 m 4D 2EM IO 41 1 120km 74 mi 8 9...

Отзывы: