Applications 

Optical fiber is immune to EMI/RF interference, ground loops, and high voltage surges from lightning or 
ground faults, and is ideal for electrically noisy environments such as near large power sources, electrical 
motors, and radio communications equipment. Using fiber optic cable provides long distance service (up 
to 120km/74mi.) without any additional equipment. 

Safety benefits of fiber optics 

Placement of all-dielectric fiber optic cable (instead of copper) completely eliminates the presence of a 
remote ground, which dramatically increases safety of personnel and reliability of equipment. By using 
fiber optic cable, the DIN Fiber Link system provides absolute electrical isolation. 

Application Diagrams 

The diagram below shows a typical configuration of the 4 Wire Data with E&M and I/O system.

 

RLH 4 Wire Data with E&M Application Diagram

 

POWER

FIBER

FIBER LINK

INPUT

OUTPUT

INPUT

OUTPUT

I/O

1

2

TX

RX

4W DA

TA

FIBER

POWER

FIBER

FIBER LINK

INPUT

OUTPUT

INPUT

OUTPUT

I/O

1

2

TX

RX

4W DA

TA

FIBER

Redundant

Power Supply 

Inputs

Redundant 

Power Supply

Inputs

RLH 4 Wire Data

Fiber Link

Up to 74 miles / 120km

Over Fiber Optic Cable

2 Channels

Central 

O

ce

2 Channels

RTU

4 Wire

600 Ohm 

Audio Signal

4 Wire

600 Ohm 

Audio Signal

RLH 4 Wire Data

Fiber Link

 (B) Output

 (A) Input

Copper Pairs

Output (A)
Input (B)

Copper Pairs

 

RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

 

Page 

"

3

Содержание 2 Channel 4 Wire Data with E&M and I/O

Страница 1: ...and made in the U S A and covered by our Limited Lifetime Warranty Key Features Hardened to operate in 40 F to 158 F 40 C to 70 C System power options 24 48VDC and 125 VDC Multimode or single mode fi...

Страница 2: ...ng connections to this device Guidelines for handling terminated fiber cable Do not bend fiber cable sharply Use gradual and smooth bends to avoid damaging glass fiber Keep dust caps on fiber optic co...

Страница 3: ...y using fiber optic cable the DIN Fiber Link system provides absolute electrical isolation Application Diagrams The diagram below shows a typical configuration of the 4 Wire Data with E M and I O syst...

Страница 4: ...VDC or 125VDC depending on model Flat head screwdriver for connection wiring Phillips screwdriver for attaching to wall optional Physical layout POWER FIBER FIBER LINK INPUT OUTPUT INPUT OUTPUT I O 1...

Страница 5: ...put signal and RX is the input signal Single fiber models combine input and output signals over one fiber strand Connect fiber cables to the correct TX and RX ports On dual fiber models the TX port of...

Страница 6: ...us LED s located on the upper and lower ends of the RJ 45 Socket The upper LED is ON when the input is active and OFF when no input is present The lower LED is ON when the E M output is closed and OFF...

Страница 7: ...load wiring prior to installation or maintenance Connect power The system accepts a 24 48VDC or 125VDC local power source depending on the model The power inputs are identified on the top of the devic...

Страница 8: ...tatus Description POWER Power ON System Power OK FIBER Fiber Optic Link ON Fiber Link is Connected OFF Fiber Link is Disconnected INPUT Input Sensor ON Input On Active OFF Input Off OUTPUT Output Rela...

Страница 9: ...input and output Insertion Loss 0dB 0 5dB each direction Overload Level 8dBm into 600 Ohms E M Input 24 48VDC 3000Vrms optically isolated E M Output 1500VRMS isolation by normally open solid state re...

Страница 10: ...20km 12 4 mi 8 9 m A 4D 2EM IO 10 1 B 4D 2EM IO 11 1 60km 37 mi 8 9 m A 4D 2EM IO 14 1 B 4D 2EM IO 15 1 Single mode SC 20km 12 4 mi 8 9 m 4D 2EM IO 40 1 60km 37 mi 8 9 m 4D 2EM IO 41 1 120km 74 mi 8 9...

Отзывы: