background image

Connect wire pairs for contact closure 

DO NOT APPLY VOLTAGE

 to the input contact terminals or the system maybe damaged. 

The contact terminals may be removed and accept wire sizes 16~26 AWG. 

Fully seat the terminal block back into the connector before operating the system.. 

Input 

The input acts as a dry contact sensor, it will sense a relay or contact closure without any external 

power source. No voltage should be applied to the input terminals as they provide the necessary 

wetting voltage. 

Check to ensure the resistance on the copper pairs being used does not exceed 100 Ohms.  

Output

 

The output is a normally open relay.  

Ensure the output relays maximum load of 60 watts or 62.5VA is not being exceeded.  

Disconnect all power to load wiring prior to installation or maintenance. 

Connect power 

The system accepts a 24-48VDC or 125VDC local power source depending on the model. The power 
inputs are identified on the top of the device, near the alarm terminals and are labeled PWR 1 and PWR 2. 
Either or all of them may be used to the power the device.  

Connect the leads of the power source to the screw down terminals on top of the DIN device. For ease of 
installation, the terminal block may be removed by pulling it straight out. If removed, seat the terminal 
block firmly into the connector before applying power. Once power is applied the power LED will turn on.  

Note:

 The power terminals are not polarity sensitive. The positive or negative lead of the power source 

may be connected to either terminal of the power connectors.  

"

 

Detail of Power Terminals

PWR 1

PWR 2

NO

-

+

-

+

COM

NC

ALARM

 

RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com

 

Page 

"

7

Содержание 2 Channel 4 Wire Data with E&M and I/O

Страница 1: ...and made in the U S A and covered by our Limited Lifetime Warranty Key Features Hardened to operate in 40 F to 158 F 40 C to 70 C System power options 24 48VDC and 125 VDC Multimode or single mode fi...

Страница 2: ...ng connections to this device Guidelines for handling terminated fiber cable Do not bend fiber cable sharply Use gradual and smooth bends to avoid damaging glass fiber Keep dust caps on fiber optic co...

Страница 3: ...y using fiber optic cable the DIN Fiber Link system provides absolute electrical isolation Application Diagrams The diagram below shows a typical configuration of the 4 Wire Data with E M and I O syst...

Страница 4: ...VDC or 125VDC depending on model Flat head screwdriver for connection wiring Phillips screwdriver for attaching to wall optional Physical layout POWER FIBER FIBER LINK INPUT OUTPUT INPUT OUTPUT I O 1...

Страница 5: ...put signal and RX is the input signal Single fiber models combine input and output signals over one fiber strand Connect fiber cables to the correct TX and RX ports On dual fiber models the TX port of...

Страница 6: ...us LED s located on the upper and lower ends of the RJ 45 Socket The upper LED is ON when the input is active and OFF when no input is present The lower LED is ON when the E M output is closed and OFF...

Страница 7: ...load wiring prior to installation or maintenance Connect power The system accepts a 24 48VDC or 125VDC local power source depending on the model The power inputs are identified on the top of the devic...

Страница 8: ...tatus Description POWER Power ON System Power OK FIBER Fiber Optic Link ON Fiber Link is Connected OFF Fiber Link is Disconnected INPUT Input Sensor ON Input On Active OFF Input Off OUTPUT Output Rela...

Страница 9: ...input and output Insertion Loss 0dB 0 5dB each direction Overload Level 8dBm into 600 Ohms E M Input 24 48VDC 3000Vrms optically isolated E M Output 1500VRMS isolation by normally open solid state re...

Страница 10: ...20km 12 4 mi 8 9 m A 4D 2EM IO 10 1 B 4D 2EM IO 11 1 60km 37 mi 8 9 m A 4D 2EM IO 14 1 B 4D 2EM IO 15 1 Single mode SC 20km 12 4 mi 8 9 m 4D 2EM IO 40 1 60km 37 mi 8 9 m 4D 2EM IO 41 1 120km 74 mi 8 9...

Отзывы: