![RJG Lynx LES-B-127-125 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/rjg/lynx-les-b-127-125/lynx-les-b-127-125_product-manual_1466485051.webp)
Product Manual | Lynx™ Embedded Sensors LES‑B‑127‑50/125/500/2000
43
SENSOR INSTALLATION CHECK—CLAMP PLATE (HEAD‑TO‑HEAD) INSTALLATION (
continued
)
Verify that the each sensor, transfer pin, and ejector pin pocket is machined correctly.
1.
Protrusion Test (without sensor)
With the ejector and transfer pins installed, the ejector plate in injection position, and
the ejector plate fixed towards clamp plate, press the ejector and transfer pin together,
towards the cavity; the ejector pin should protrude 0.008–0.01” (0,2–0,3 mm).
2.
Indentation Test (without sensor)
Ejector
Retainer
Plate
Clamp
Plate
Ejector
Plate
B Plate
or
Cavity
Insert
Ejector Pin
Transfer Pin