M
MAN-2V3B-4.1V REV (C)
5
WARNING
A painful burn can be caused by touching any of the cylinder heads or
discharge gas lines from the heads to the inter/aftercooler.
Do not stick hand inside distance piece when unit is running. Metal
slingers on piston rods will crush fingers.
3.3
NORMAL OPERATING PRESSURE RANGES:
Suction:
30-40 psig
1st Stage:
190-250 psig
2nd Stage:
700-820 psig
3rd Stage
up to 2500 psig
Back Pressure Regulator setting: 1800 psig (approximate)
It is recommended that a log be kept, noting operating pressures and
maintenance done versus hours of compressor operation. If pressures do not
fall within the above ranges, or vary from your historical pressures, check
Chapter 6, Troubleshooting, for corrective action.
3.4
RELIEF VALVE SETTINGS:
Stage
Symbol
Set Point
Suction
RVI
50 Psig
1st Stage
RV1
300 Psig
2nd Stage
RV2
1000 Psig
3rd Stage
RV3
2800 Psig
Содержание RIX 2V3B-4.1V Series
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 70: ...P N 515 910 P N 515 911 P N 515 792 P N 515 829 X515 910 X515 911 X515 792 X515 829...
Страница 71: ......
Страница 72: ......
Страница 73: ...P N 76 713 X76 713...
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......