background image

13

3.6.2   Setting the temperature 

3.6.3  The Spa screen  

(user functions)

All Equipment Access 
The Spa Screen shows all available equipment to control, as well as other 
features, like Invert. The display shows icons that are related to the equipment 
installed on a particular spa model, so this screen may change depending on 
the installation. The icon buttons are used to select and control individual 
devices. Some devices, like pumps, may have more than one ON state, so the 
icon will change to reflect the state that the equipment is in. Below are some 
examples of 2-speed Pump indicators.

If the Spa has a Circ Pump, a Circ Pump Icon will appear to indicate its activity, 
but outside of Priming Mode, the Circ Pump cannot be controlled directly.

NOTE: The icon for the pump that is associated with the heater (Circ or P1 Low) 
will have a red glow in the center when the heater is running.

Commissioning and Operation

Navigation 

Navigating the entire menu structure is done by touching the screen. When 
a text item is shown in white on the main screen, it is selectable. The menu 
selections on the right side of the screen can be selected. Select one of these 
to enter a different screen with additional controls.
Most menu screens time out and revert to the main screen after 30 seconds 
of no activity. The only item that can be changed on the left side of the Main 
Screen is the Set Temperature. Touch either the set temperature line or the 
water temperature to go to the Set Temperature screen. See next page.

Messages

At the bottom of the screen, messages may appear at various times. Some of 
these messages must be dismissed by the user (see pages 22-26).

Содержание Starto 2.0

Страница 1: ...l P O R T A B L E S P A S R I V I E R A S P A S S T R A T O W A V E Pr e fa b r i c at e d Sw i m m i n g p o o l s Wh i r l p o o l s AT TE NTIO N This is a preliminary version subject to modificatio...

Страница 2: ...3 6 9 Frost protection Page 19 3 6 10 Auxiliary control panel s Page 20 3 6 11 Locking the operating keys Page 20 3 6 12 The Fault Log Page 21 3 6 13 Information Page 22 3 6 14 The cleaning cycle Pag...

Страница 3: ...1 Strato 2 0 1 Technical Drawings Information Additional information is available from our technical customer service department We reserve the right to perform production changes and improvements wi...

Страница 4: ...0 65 1070 1 2 430 530 2420 Technik Aufstellbereich mit ausgezogenen Hardtopauflagen inkl Daybed RivieraSpas Portable 1 2 Strato 2 3 incl Daybed technique Required space for pool with extracted support...

Страница 5: ...10 ca 3640 65 1070 1 2 430 530 2390 Aufstellbereich mit ausgezogenen Hardtopauflagen inkl Daybed RivieraSpas Portable 1 3 Wave 2 0 Required space for pool with extracted supports for the pool cover in...

Страница 6: ...n the whirlpool can not be higher than 40 C The chlorine level should not be higher than 300 mg l If you want to install a private whirlpool in a situation that is different from the one described abo...

Страница 7: ...transport or tilt the Whirlpool on its edge When removing the packaging film make sure that this is only cut in the region of the transport pallet After removing the packaging film remove the lower cl...

Страница 8: ...the corner pieces of the surround elements on the front of the pool Unpack cover carefully Please make sure that the packaging film is not cut with a sharp knife or blade This could cause damage to t...

Страница 9: ...During the priming mode the heater is disabled to allow the priming process to be completed without the possibility of energizing the heater under low flow or no flow conditions Nothing comes on auto...

Страница 10: ...ets faceplate can be rotated clockwise to close them off Turn the anit clockwise to open the water flow The nozzles can be adjusted to a Center position to reduce pressure from that jet This may howev...

Страница 11: ...are locked The Menu choices on the right can be selected and the screen will change to show more detailed controls or programming functions Note After 30 minutes the display will automatically go int...

Страница 12: ...onal controls Most menu screens time out and revert to the main screen after 30 seconds of no activity The only item that can be changed on the left side of the Main Screen is the Set Temperature Touc...

Страница 13: ...ntrolled directly NOTE The icon for the pump that is associated with the heater Circ or P1 Low will have a red glow in the center when the heater is running Commissioning and Operation Navigation Navi...

Страница 14: ...whether it is labeled or not it means Back or Exit It appears on editing screens before you have changed any value as well as on all other screens Values Increment Decrement If an Up or Down button i...

Страница 15: ...the right side of the screen indicates the relative position of the page Values Increment Decrement If an Up or Down button is shown and pressed when on an editing page and a value has been selected h...

Страница 16: ...orporates two temperature range settings with independent set temperatures The specific range can be selected on the Settings screen and is visible on the Main Screen in the upper right corner of the...

Страница 17: ...ling stattfindet kann das Temper aturdisplay die aktuelle Temperatur nur anzeigen wenn die Heizungspumpe f r ein bis zwei Minuten gelaufen ist Wenn die Heizungspumpe automatisch anf ngt zu laufen zum...

Страница 18: ...s not flowing from the jets in the spa do not allow the pumps to continue to run Turn off the pumps and repeat the process Note Turning the power off and back on again will initiate a new pump priming...

Страница 19: ...y not coincide with the start of the filter cycle If the Filter Cycle 1 duration is set for 24 hours enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to begin The Meanin...

Страница 20: ...example in the 24 hour circulation mode and the water temperature is 3 F 1 3 C below the set temperature then the heating will not turn off during the filter cycle Specific Buttons for Specific Device...

Страница 21: ...or Panel if it says On than press in the middle of the screen for at least 5 seconds The Fault Log is a record of the last 24 faults that can be reviewed by a service tech Use the Up and Down buttons...

Страница 22: ...nfiguration Signature Displays the checksum for the system configuration file Heater Voltage Feature not used on CE rated systems Displays the operating voltage configured for the heater Heater Wattag...

Страница 23: ...isplay Change the clock between 12 hr and 24 hr display Reminders Turn the reminder messages like Clean Filter On or Off Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When...

Страница 24: ...ential freeze condition has been detected or the Aux Freeze Switch has closed All water devices are activated In some cases pumps may turn on and off and the heater may operate during Freeze Protectio...

Страница 25: ...low The heater is dry M027 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must reset the message to restart heater start up See Flow R...

Страница 26: ...ice Sensor A Fault Senor B Fault Sensor A M031 Sensor B M032 A temperature sensor or sensor circuit has failed Call for Service Communication error The panel does not receive communication data from t...

Страница 27: ...Press the message text to reset the message The clock has failed M020 Contact your dealer or service organization Configuration error Spa will not Start Up Contact your dealer or service organization...

Страница 28: ...ed on a regular basis to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on...

Страница 29: ...vice check up May appear on a regular schedule Do a service check up as instructed by the manufacturer The audio system consists of two tweeters and a subwoofer they are mount ed below the spa The dat...

Страница 30: ...lly so that vinyl is not damaged Please use the Sunstar vinyl care or saddle soap as an additive for the cleaning water Please do not use care products that the Vinyl attack After washing leave the ha...

Страница 31: ...ore headrests and covers should be taken out and stored dry when not using the spa The covers should be regularly washed Washing instructions are sewn into each cover Note The covers are wearing parts...

Страница 32: ...tted with very fine non woven filter cartridges which keep impurities out of the water The cartridge itself is capable of lasting many years but should be changed every 12 months A set of replacement...

Страница 33: ...ator switches off when the massage pumps are activated Through the disinfection of the water in the whirlpool salt deposits build up To keep this build up as low as possible fresh water should be adde...

Страница 34: ...ces should be cleaned sand lightly and remove any sanding dust For deeper injuries or discoloration due to excessive mechanical wear sand the surface and fill with glaze FVG in the corresponding colou...

Страница 35: ...and piping completely empty Open the drain screw on the massage pump Remove clean and dry the filter cartridge Fit and fix the hardtop cover if necessary keep free of snow To restart close all valves...

Страница 36: ...should be approximately 20 minutes if the water is 38 C no more than 10 12 minutes Each bath should be followed by a cool down period of the same length of time This can be done either by going out i...

Страница 37: ...gether Thus it does not matter if the pin J79 J78 or J77 in the green area is used To switch to 400 V remove the both connections between blue and brown area and connect J60 and J41 to the green area...

Страница 38: ...1 J108 J24 J107 K12 K7 Stromversorgung 230 V 400 V Zusatzplatine Jet 2 Jet 3 Heizer 3 KW Fernbedienung Zusatzschalter Display Panel Bluetooth Steuerger t Jet 1 230 V AV Filterpumpe Ozon Gebl se Aktivi...

Страница 39: ...ge every 12 months Water change every 3 months Injectors can calcify check and clean Ozonator is a consumable check its operation 4 Cover Covers have a finite life Regular cleaning and maintenance wit...

Страница 40: ...Logovorlage www rivierapool com One of the leading German manufacturers of prefabricated swimmingpools pool equipment and whirlpools Member in the BSW Date 16 08 16...

Отзывы: