XH2-240 Hardened Access Points
14
Warnings
GENERAL SAFETY GUIDELINES
POWER
!
WARNING
: This warning symbol means danger. You are in a situation that could cause bodily injury.
Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be
familiar with standard practices for preventing accidents.
!
WARNING
: Only trained and qualified personnel should be allowed to install, replace, or service this
equipment.
!
WARNING
: Ultimate disposal of this product should be handled according to all national laws and
regulations.
!
WARNING
: Incorrect installation of Riverbed Access Points may invalidate FCC, CE mark, or other
regulatory compliance approvals. Customers are responsible for any legal violations from operation of
un-approved equipment or incorrect installation.
!
WARNING
: Do not operate the Access Point near unshielded blasting caps or in an explosive
environment unless the device has been modified to be especially qualified for such use.
!
CAUTION
: Suitable for use in environmental air space in accordance with Section 300.22.C of National
Electrical Code, and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, C22.1.
!
CAUTION
: Supplied watertight adapters must be used on all input/output connections to the Access
Point.
!
CAUTION
: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS.
!
WARNING
: Read the installation instructions before connecting the system to the power source.
!
WARNING
: Installation of the equipment must comply with local and national electrical codes.
!
WARNING
: This equipment must be externally grounded using a customer-supplied ground wire
before power is applied. Contact the appropriate electrical inspection authority or an electrician if you
are uncertain that suitable grounding is available.
!
WARNING
: Do not work on the system or connect or disconnect cables during periods of lightning
activity.
!
WARNING
: To ensure proper PoE power is delivered to the Access Point, use only No. 26 AWG or larger
Ethernet (Shielded CAT5E, CAT6) cable.
!
CAUTION
: When the Access Point is installed outdoors or in a wet or damp location, the AC branch
circuit that is powering the Injector should be provided with ground fault protection (GFCI), as required
by Article 210 of the National Electrical Code (NEC).
!
CAUTION
: Riverbed PoE Injectors rely on the building's installation for over current protection. Ensure
that a fuse or circuit breaker no larger than 120 VAC, 15A (U.S.) or 240 VAC, 10A (International) is used
on all current-carrying conductors.