SteelConnect SDI-2030 and SDI-5030 Gateway Overview | 9
SteelConnect SDI-2030 and SDI-5030 gateway LEDs
SteelConnect SDI-2030 and SDI-5030 gateway front panel LEDs
Figure 1-4. Front panel LEDs
This table describes the LEDs for the control panel on the SteelConnect SDI-2030 and SDI-5030
gateways.
Control panel descriptions
LED description
System ID button with
integrated LED
Maintenance = blue.
Turns the integrated ID LED and the blue server board ID LED on and off. The ID
LED identifies the gateway for maintenance when installed in a rack of similar
appliances. You can also turn on and turn off the ID LED remotely by using the
Intelligent Platform Management Interface (IPMI)
chassis identify
command,
which causes the LED to blink for 15 seconds.
A duplicate system ID LED is on the back of the gateway to the left of the video
port.
NMI button (recessed, tool
required for use)
Puts the gateway in a halt state and issues a nonmaskable interrupt (NMI). This
state helps when performing diagnostics for a given issue where a memory
download is necessary to determine the cause of the problem. To prevent an
inadvertent system halt, the NMI button is located behind the front control
panel faceplate and is only accessible with the use of a small tipped tool such as
a pin or paper clip.
NIC 1 activity LED (port 6
activity LED)
Maps to port 6 on the rear panel.
Link = green.
Activity = blinking green. The blink rate is consistent with the amount of
network activity.
System cold reset button
(recess, tool required for use)
Reboots the gateway.
System status LED
Shows the current health of the server system.
Healthy = green.
Degraded = yellow.
Critical = blinking yellow.
Power button with integrated
LED
System on = green.
System off = no light.