74 | Installing Network Cards in SteelHead GX and xx70, SteelHead SD, SteelCentral, Interceptor 9600, and SteelFusion Core 3500
Identifying interface names
For detailed information, see the
Riverbed Command-Line Interface Reference Manual
.
2. Enter enable mode. At the system prompt, enter the following command:
amnesiac > enable
amnesiac #
3. Verify that the NIC is correctly installed.
For example, to verify the NICs on a SteelHead 5070, at the system prompt enter the following
command:
amnesiac # show hardware all
Hardware revision: A
Mainboardlatform Tarpon 2UAGB Motherboard 2U 2.5 CI, 425-00270-01
Slot 0: .......... 2 Port Copper GigE Gen2 PCIe Non-Bypass Module, Integrated
Slot 1: .......... 4 Port Copper GigE Gen2 PCIe Network Bypass Card, 410-00115-01
Slot 2: .......... 2 Port SR Fiber 10 GigE Gen2 PCIe Redirector Card, 410-00302-03
Note:
Enter the
in-path reset-iface
command in configuration mode in the CLI to reset the main interface and
recognize all ports.
Identifying interface names
The interface names for the network add-on cards vary according to the product.
Product
Interface names
SteelHead
The interface names are a combination of the slot number and the port pairs:
(lan<slot>_<pair>, wan<slot>_<pair>). For example, if a four-port NIC is located
in slot 1 of your appliance, the interface names are lan1_0, wan1_0, lan1_1, and
wan1_1 respectively.
SteelCentral
AppResponse
The interface name is a combination of the slot number and the port number within
the slot: monNN_MM. Where NN is the slot number and MM is the port number within
the slot. The port number is named from left to right, starting with 0. For example,
mon2_0 is the left-most interface of a NIC card installed in slot 2.
SteelCentral NetProfiler
The SCNP-04270 and SCNP-04270-EXP appliances do not have interface names.
SteelCentral Flow
Gateway
You can install an additional two-port 10-GbE card in the SCFG-02270 appliance. The
two ports are named, from left-to-right: primary and aux. These ports replace the on-
board ports with the same name.
SteelCentral NetExpress The interface names are a combination of the slot number and the port pair
(mon<slot>_<pair>).
Содержание NIC LR
Страница 8: ...8 Contents ...
Страница 16: ...16 Getting Started Troubleshooting ...
Страница 48: ...48 Installing Network Cards in xx80 Appliances Identifying interface names ...
Страница 106: ...106 Installing NICs in SteelHead xx50 Appliances Installing NICs in 3U xx50 appliances and Interceptor 9350 ...