26 Publication:
AMEN00102 2017-07-06
MAINTENANCE
Hydraulic
Continued
Schematic – Stand Alone Power Unit
M
#6SAE
STAND ALONE POWER UNIT
RESERVOIR:
1 GALLON
VERTICAL & HORIZONTAL
MOUNT
SCREEN AND MAGNET
120V 2POS 4WAY SOLENOID
RAISE/LOWER SELECTOR
SOLENOID IS POWERED
DURING LOCKED AND
LOCKING STATES.
HOOK CYLINDER
1.25 x 3 x .5 ROD
AUXILLARY MANIFOLD
MOUNTED ON CARRIAGE
#6SAE
HOLDING
CHECK
VALVE,
50PSI
VMS
ORIFICE,
.020
ADJUSTABLE
SYSTEM RELIEF,
675 PSI
MOTOR:
120/1/60
MAIN SUPPORT
CYLINDER, RH
3.5 x 9
MAIN SUPPORT
CYLINDER, LH
3.5 x 9
P
#6SAE
PCC
CV
PP
CV
L
#6SAE
#4SAE
HR
#4SAE
RV
HL
NOTE: THIS HOSE IS
A #4SAE HOSE.
Pilot To Close
Check Valve
Pilot To Open
Check
Valve
Check
Valve
Relief Valve,
2000 PSI
P
L
MR
#6SAE
ML
#6SAE
MR
#6SAE
#6SAE
ML
(MAIN RAISE)
(MAIN LOWER)
(MAIN RAISE)
(MAIN LOWER)
(PRESSURE)
(PRESSURE)
(LOWER)
(LOWER)
(HOOK LOWER)
(HOOK RAISE)
RAISE
(SOL1)
Содержание STR-4200 Dok-Lok
Страница 23: ...Rite Hite Owner s Manual STR 4200 Dok Lok Publication AMEN00102 2017 07 06 23 ...
Страница 30: ...STR 4200 Dok Lok Owner s Manual Rite Hite 30 Publication AMEN00102 2017 07 06 ELECTRICAL Restraint Micro Board ...
Страница 34: ...STR 4200 Dok Lok Owner s Manual Rite Hite 34 Publication AMEN00102 2017 07 06 ELECTRICAL Wiring Approach Vu ...