STR-4200™ Dok-Lok
®
Owner's Manual
Rite-Hite
®
18 Publication:
AMEN00102 2017-07-06
MAINTENANCE
Troubleshooting
Continued
Component Testing – Switches/Sensors
1 Set multimeter to “RX1” scale for “Continuity Test”
2 Attach multimeter leads to white and black wires of
switch connector:
Magnetic Sensor (SW1,SW2)
No magnet present = No meter reading
Magnet present = a "Full Scale" meter reading
Mechanical Limit Switch (SW3)
Plunger released = No meter reading
Plunger depressed = a "Full Scale" meter reading
sensing
switch
magnet
white
black
Magnet
Sensing
Switch
White
Black
red (not used)
white
black
green
limit switch body
wire harness
mounting
bolt holes
fixed guide
plunger w/roller
Fixed Guide
Plunger with Roller
Mounting
Bolt Holes
Wire Harness
Limit Switch Body
Green
Black
White
Red (not used)
•
Green (ground) wire of limit switch does not have to be
tested A continuity test lamp may be used instead of a
multimeter
•
Sensor 1 (SW1) and Limit Switch 3 (SW3) are wired in series
into SW1 input on micro control board
Limit Switch and Hook Positions
HOOK POSITION
LOCK SENSOR
(SW1)
UNLOCK SENSOR
(SW2)
SUPPORT LIMIT SWITCH
(SW3)
INSIDE
LIGHT
OUTSIDE
LIGHT
CONTROL BOX
HORN
1 Stored
Off
On
Open / Released
Red
Green
Off
2 No Hook (No Support)
Off
Off
Open / Released
Red
Red
On
3 Hooked (90° Support On)
On
Off
Closed / Depressed
Green
Red
Off
4 No Hook (Support On)
Off
Off
Closed / Depressed
Red
Red
On
Figure 7