Rite-Hite
®
Owner's Manual
STR-4200™ Dok-Lok
®
Publication:
AMEN00102 2017-07-06
17
MAINTENANCE
Troubleshooting
Continued
Sensor Adjustments
Position support limit switch
so switch is activated when
cylinder rod is extended and
resting in support pocket.
NOTE:
- Adjusting switch too high could
result in damage to switch.
- A 3/4" deep well socket or section
of 1" OD round works well to
simulate engaged cylinder rod.
.34
(+.06)
(-.00)
Support Limit
Switch (SW3)
Unlock Sensor
Lock Sensor
Limit Switch Flag
Lock Sensor
(SW1)
Unlock
Sensor
(SW2)
Support Limit Switch
(SW3)
Limit Switch Flag
34
(+06)
(-00)
Position support limit switch
so switch is activated when
cylinder rod is extended and
resting in support pocket.
NOTE:
- Adjusting switch too high could
result in damage to switch.
- A 3/4" deep well socket or section
of 1" OD round works well to
simulate engaged cylinder rod.
.34
(+.06)
(-.00)
Support Limit
Switch (SW3)
Unlock Sensor
Lock Sensor
Limit Switch Flag
Position support limit switch so
switch is activated when cylinder
rod is extended and resting in
support pocket
Use a spacer (eg 3/4in deep well socket or section of 1in
[25mm] OD round) to test location of cylinder rod when it
is engaged
Adjusting switch too high could result in damage to switch