TABLE OF CONTENTS
INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . .3
FRAME INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
LIMIT SWITCH ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . .9
TROUBLESHOOTING / MAINTENANCE . . . . . . . . . . . . . .10
ELECTRICAL DRAWINGS . . . . . . . . . . . . . . . . . . . . . . . . .12
SERVICE PARTS/LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
ARCHITECTURAL DRAWING . . . . . . . . . . . . . . . . . . . . . . .19
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .last page
NOTICE TO END USER
Our mission is to “Improve Industrial Safety, Security and
Productivity Worldwide Through Quality and Innovation.”
Thank you for purchasing the FLASHFOLD™ barrier unit by
RITE-HITE
®
MACHINE GUARDING. The FLASHFOLD is
intended to provide isolation to employees from flying debris
and flash protection in welding areas or machine guarding
areas. This curtain is intended to open from the bottom and
close or separate going up to provide safety and access to work
areas.
The FLASHFOLD, which is supplied with a motor assembly,
frame, curtain and offers an optional interlock switch, curtain
guides and a control box. The information contained in this
manual will allow you to operate and maintain the door in a
manner which will insure maximum life and trouble free operation.
When ordering parts through Aftermarket or Warranty
department, always include your model serial or SO# to be sure
that you receive the correct parts. The SO# and serial # for your
product is located on a label on the side of the control box. The
actual parts used on your door may be different than shown in
this manual due to special engineering or product improvement.
Your local representative provides a Planned Maintenance
Program (P.M.P.) which can be fitted to your specific operation.
Call your local representative or RITE-HITE MACHINE
GUARDING at 1-563-587-4401 or toll free at 1-800-553-5560. If
any procedures for the installation, operation or maintenance of
the FLASHFOLD system have been left out of this manual or
are not complete, contact Technical Support at 1-563-589-2722.
FEATURES
- Automatic, ergonomically correct, allows hands free operation.
- Heavy-Duty, U.V. protected curtain fabric protects operator
from intense light and flying debris.
- Smooth, fast opening operation.
TOOLS AND MATERIAL REQUIRED
7/16” & 9/16” [11 & 14] Open End Wrench or Ratchet Wrench
7/16” & 9/16” [11 & 14] Socket Set
Allen Wrench Set
13mm Socket
Phillips Screwdriver
Straight Screwdriver (small 1/8” [3] blade)
Hammer Drill (Optional)
Extension Cord (Optional)
3/8” or 1/2” [10 or 13] Masonry Bits (Optional)
Drill (3/8” or 1/2”) [10 or 13] w/Phillips Bit
5/16” [8] Hex Driver Bit For Drill
Tape Measure 25’ [7620] Minimum
Wire Strippers and Side Cutters
Retaining Ring Pliers
Carpenters Level
Water Level
Multi-Meter
Step Ladder
Hardware for mounting, shimming and anchoring to the floor are
not provided.
LOCKOUT/TAGOUT PROCEDURES
The Occupational Safety and Health Administration requires
that, in addition to posting safety warnings and barricading the
work area, the power supply has been locked in the OFF posi-
tion or disconnected. It is mandatory that an approved lockout
device is utilized. An example of a lockout device is illustrated.
The proper lockout procedure requires that the person responsi-
ble for the repairs is the only person who has the ability to
remove the lockout device.
In addition to the lockout device, it is also a requirement to tag
the power control in a manner that will clearly note that repairs
are under way and state who is responsible for the lockout con-
dition. Tagout devices have to
be constructed and printed so
that exposure to weather condi-
tions or wet and damp locations
will not cause the tag to deterio-
rate or become unreadable.
Rite-Hite does not recommend
any particular lockout device,
but recommends the utilization
of an OSHA approved device
(refer to OSHA regulation
1910.147). Rite-Hite
Corporation also recommends
the review and implementation
of an entire safety program for
the Control of Hazardous
Energy (Lockout/Tagout). These
regulations are available
through OSHA publication
3120.
2
PUB. NO. 1390E APRIL 2014
FLASHFOLD
™
MODEL 1390
PRODUCT INTRODUCTION
All wiring should be installed by a qualified electrician in
accordance with all national and local electrical codes. If the
rigid conduit is installed, bonding must be maintained between
conduit and ground connections by using ground bushings
and a jumper wire. Solid 3/4” conduit is recommended
I M P O R TA N T ! ! !
Содержание FLASHFOLD 1390
Страница 11: ...PUB NO 1390E APRIL 2014 11 NOTES PAGE FLASHFOLD MODEL 1390 This page intentional left blank...
Страница 12: ...12 PUB NO 1390E APRIL 2014 FIELD WIRING DIAGRAM FLASHFOLD MODEL 1390...
Страница 13: ...PUB NO 1390E APRIL 2014 13 ELECTRICAL WIRING DIAGRAM FLASHFOLD MODEL 1390 Electrical Drawings...
Страница 17: ...PUB NO 1390E APRIL 2014 17 ARCHITECTURAL DRAWING FLASHFOLD MODEL 1390 Architectural Drawings...
Страница 18: ...18 PUB NO 1390E APRIL 2014 NOTES PAGE FLASHFOLD MODEL 1390 This page intentional left blank...
Страница 19: ...PUB NO 1390E APRIL 2014 19 NOTES PAGE FLASHFOLD MODEL 1390 This page intentional left blank...