RITE-HITE Dok-Lok STR-4000 Скачать руководство пользователя страница 7

Pub. No. 1200 — November 2005

7

RITE-HITE STR-4000 DOK-LOK Installation Manual

POSITION DOK-LOK ASSEMBLY INTO
TRACK

1.

Attach lifting chains to each side of DOK-LOK
carriage. See figure 2.

2.

Lift DOK-LOK and position above the DOK-LOK
track.

3.

Lower DOK-LOK into track until base plate is resting
on the approach.

4.

Center DOK-LOK in track.

5.

If approach is inclined, shim as shown in figure 3.

6.

If approach is declined, shim as shown in figure 3.

7.

Anchor both sides of Base Plate to approach. See
figure 4.

INSTALLATION CONT.

Figure 4 - Completing Mechanical Installation

Attach Lifting Chains

Leveler Front

Curb Angle

Embedded Mounting

Plate or Dok-Lok

Bracket

Approach

.625 Dia. Concrete
Anchors Are Required
Wherever A Plug Weld
Is Not Possible

Typ. (10) Places

Typ.

.25

.25

Across Top
Of Track

Anchor Base Plate To Approach With .625 Dia.

Concrete Anchors. Typical Both Sides.

Figure 2 - Welding Installation

.25

Shim to Base Plate

Approach

3.36”

90°

.25

Shim to Base Plate

Approach

3.36”

90°

Inclined Approach

Declined Approach

Figure 3 - Shim Base Plate

NOTE:

Base Plate Must Be Square To Track.
Shims Must Be Placed Under Each Cylinder And/Or
Spring Tube As Required.
Cylinder Should Be Loose. No Bind On Cotter Pins.

See Note

See Note

Содержание Dok-Lok STR-4000

Страница 1: ...Manual Covers Serial No 05GD150001W And Up PRINTED IN U S A RITE HITE PRINT SHOP PUBLICATION NO 1200 Copyright 2004 2005 NOVEMBER 2005 STR 4000 Dok Lok Vehicle Restraint Installation Manual MADE IN U...

Страница 2: ...the truck driver and DOK LOK vehicle restraint operator that a safe condition exists The DOK LOK vehicle restraint is operated by pressing push buttons on an inside control panel NOTICE TO USER Your l...

Страница 3: ...r become unreadable RITE HITE Corporation does not recommend any particular lockout device but recommends the utilization of an OSHA approved device refer to OSHA regulation 1910 147 RITE HITE Corpora...

Страница 4: ...arnings when work is being performed on the leveler Never be under the dock leveler platform or lip without Install the Safe T Struttm or other manufacturer approved supporting device See figure 2 If...

Страница 5: ...hin pit A shim must be inserted between the roller track plate and the leveler front subframe and then must be welded in place See page 17 b If the dock conditions DO NOT allow lights and signs to be...

Страница 6: ...ove track cover plate and weld top of track to leveler front frame angle and or pit steel NOTE 1 Figure 2 Shims must be the full length of the roller track mounting plate and base plate Minimum electr...

Страница 7: ...LATION CONT Figure 4 Completing Mechanical Installation Attach Lifting Chains Leveler Front Curb Angle Embedded Mounting Plate or Dok Lok Bracket Approach 625 Dia Concrete Anchors Are Required Whereve...

Страница 8: ...nt power unit on dock wall as shown in figure 5 using the supplied mounting bracket Power unit must be mounted on side shown and within 24 of control box If power unit location is to be under the leve...

Страница 9: ...entrances are required WIRING DIAGRAM STAND ALONE POWER UNIT FROM OUTSIDE LIGHT BOX TO POWER SOURCE OUTSIDE LIGHT BOX SEE DETAIL A INSIDE LIGHT CONTROL BOX SUPPLIED BY OTHERS 30 AMP RATED FUSED DISCON...

Страница 10: ...1 L 2 MCOM M1 SCOM SOL1 SOL2 CR4 CR5 250v 1A Fast Blow 250v 20A Slow Blow M1 SOL1 SOL2 BLK WHT 120 VAC 0 23 AMPS Raise Solenoid 1 SCom 2 Sol1 To Customer Power Supply 120v 1PH 60Hz 20 Amp 30 Amp Rated...

Страница 11: ...ER SOURCE OUTSIDE LIGHT BOX SEE DETAIL A INSIDE LIGHT CONTROL BOX SUPPLIED BY OTHERS 30 AMP RATED FUSED DISCONNECT 5 14 GA WIRES DETAIL A SUPPLIED BY RITE HITE OUTSIDE LIGHT BOX FROM CONTROL BOX SIDE...

Страница 12: ...0 23 AMPS Raise Solenoid WKX 1 SCom 2 Sol1 To Customer Power Supply 120v 1PH 60Hz 15 Amp Fused Disconnect With 1 Amp Dual Element Time Delay Fusing Supplied By Others PB3 PB2 PB1 ISA LOCK UNLOCK OSG...

Страница 13: ...6 Cycle the DOK LOK up and down to remove air from the system Add remaining hydraulic fluid Stop cycling once the support cylinders travel up and down the full length of slots without hesitation 7 Pre...

Страница 14: ...CK VALVE 50PSI VMS ORIFICE 020 ADJUSTABLE SYSTEM RELIEF 675 PSI MOTOR 120 1 60 MAIN SUPPORT CYLINDER RH 3 5 x 9 MAIN SUPPORT CYLINDER LH 3 5 x 9 2 P 6SAE PCC 1 3 CV PP 1 2 2 1 CV L 6SAE 4SAE 1 HR 4SAE...

Страница 15: ...V 4 1 1 2 2 2 SOL 1 WKX 1 RP 3 6SAE SOL2 WKV LO 4SAE T 6SAE LP 6SAE 1 LIP OUT RAMP OUT COMBINATION POWER UNIT VALVE BLOCK LOCATED ADJACENT TO LEVELER POWER UNIT Check Valve Pilot To Close Check Valve...

Страница 16: ...oid Return to Tank Port Leveler Ramp Out Port Adjustable Relief Valve NOTE LOCATED ADJACENT TO LEVELER POWER UNIT ONLY ON COMBINATION POWER UNITS Figure 15 Combination Power Unit Valve Block Assembly...

Страница 17: ...nchors Are Required If 1 or Greater DOK LOK Bracket Required A Dim Length From Top Of Pit Steel To Bottom Of Track Plate B Dim Thickness Of Shim C If Dimension C Is Greater Than 3 inches Consult Facto...

Страница 18: ...y with height of the channels c If site conditions warrant a spacer different than shown consult the factory 2 Weld both sides of Base Plate Support Spacer to Base Plate and anchor to approach See fig...

Страница 19: ...ench drain is below the base plate embed PVC pipe in concrete for drainage Concrete should extend a minimum of 6 inches to either side of of mounting plate NOTE If concrete can not be used consult fac...

Страница 20: ...acities and or specified design parameters and not otherwise abused Periodic lubrication and adjustment is the sole responsibility of the owner This warranty is RITE HITE s exclusive warranty RITE HIT...

Отзывы: