[ 14-2 ]
MZ870 / MZ890 / MZ1070 / MZ1090
(Revision 0.9)
MASTER MAKING SECTION
Master making unit upper cover set sensor, located on the Cutter cover assembly is changed from an
interrupt sensor to a Micro switch, as it is on the EZ machines.
Removal Procedure
1. Pull out the Master making unit from the machine, turn OFF the machine power and disconnect the
power cord from the machine.
2. Open the Master making upper unit and remove the Cutter cover assembly.
3. Disconnect the connector and remove the Master making upper cover safety switch together with the
switch bracket. (1 screw)
Removing the Master Making Upper Cover Safety Switch
Maser making unit upper cover safety switch
Cutter Cover Assembly
(Top View)