Страница 3: ...primary value 3 1 2 2 PotentialTransformersecondary value 3 1 3 CommunicationParameterSetting 3 1 3 1AddressSetting 3 1 3 2 RS485Baudrate 3 1 3 3 RS485Parityselection 3 1 4 OutputTypeSelection 3 1 4...

Страница 4: ...output 2 3 2 Programming Via Programming port available at front of Transducer using optional PRKAB601 Adapter Installation 5 1 EMC Installation Requirements 5 2 Case Dimension 5 3 Wiring 5 4 Auxiliar...

Страница 5: ...rogrammed at siteforthefollowing PT Primary PT Secondary Input Characteristics i e start end and elbow value of Input and Output parameters i e as Voltage or as Current and start end and elbow valueof...

Страница 6: ...ent Table 1 Measured parameters Measured parameters Unit of Measurement Voltage V 2 Input and Output screens In normal operation the user is presented with display test screen followed by version scre...

Страница 7: ...onEntryStage 3 1 1 PasswordProtection 3 1 1 1PasswordVerification Password protection can be enabled to prevent unauthorised access to set up screens by default password protectionisnotenabled Program...

Страница 8: ...cial case where the Password is 0000 pressing the Up key when prompted for the first digit will advance tothe PasswordSet Confirmed screen Enter Password first digit entered prompt for second digit De...

Страница 9: ...ughto9 thevaluewill wrapfrom9roundto0 Pressing the Up key will advance the operation to the PasswordSet Confirmed andsetthefourthdigit Password Set Confirmed Pressing Down key will enter to the New ch...

Страница 10: ...digit will be flashing Pressing the Down key will scroll the value of the second digit from 0 through to 9 the valuewillwrapfrom9roundto0 Pressing the Up key will advance the operation to the nextdigi...

Страница 11: ...n this caseto 1 New changedPasswordconfirmed Pressing the Down key will re enter to the New Change Password entrystage Pressing the Up key will confirm New Password advance to the Potential Transforme...

Страница 12: ...ressingthe Down keywill scrollthevalueofthefirstdigit from0throughto9 thevaluewill wrapfrom9roundto0 Pressingthe Up keywill advance the operation to the next digitandsetthefirstdigit inthis caseto 1 E...

Страница 13: ...ry value third digit entered promptingforfourthdigit Denotes that digit will be flashing Pressing the Down key will scroll the value of the fourth digit from 0 through to 9 the value will wrapfrom9rou...

Страница 14: ...ssingthe Down keywill scrollthevalueoftheSecond digitfrom0throughto5 the valuewillwrapfrom5roundto0 Pressingthe Up keywill advancetheoperationtothenext digitandsettheseconddigit inthiscaseto 5 EnterNe...

Страница 15: ...fourthdigit inthiscaseto 0 New changedPTSecondaryvalueconfirmed Pressing the Down key will re enter to the New Change PT Secondary value edit mode Pressing the Up key will confirm New PT Secondary val...

Страница 16: ...hevaluewill wrapfrom2roundto0 Pressing the Up key will advance the operation to the next digit and set the second digit inthiscaseto 0 EnterNew ChangeAddress value seconddigitentered promptingfor thir...

Страница 17: ...Change Addressvalueedit mode Pressingthe Up keywill confirmNewAddressvalueand advancetoBaudRateselection section3 1 3 2 3 1 3 2RS485Baudrate This screen allows the user to set BaudRateofRS485port The...

Страница 18: ...the Parity stopbitedit modeandscrollthevalue through odd oddparitywithonestopbit no 1S noparitywithonestopbit no 2S noparitywithtwostopbit E evenparitywithonestopbit Pressing Up key accepts the presen...

Страница 19: ...e Output 2 typeselection section3 1 4 2 Output1Type confirmation Pressing Down key will re enter into Output 1 type Edit mode Pressing the Up key will set the type and advance to the Output2typeselect...

Страница 20: ...End value of Input can be set 80 to 120 of set PT secondary value Pressing the Down key will enter the New Change End valueofInputedit mode Pressing Up key will confirm the present value as End value...

Страница 21: ...om9roundto0depending onthevalueofseconddigit Pressing the Up key will advance the operation to the nextdigitandsetthethirddigit inthiscaseto 0 Enter New Change End value of Input third digit entered p...

Страница 22: ...rtvalueofInput Start value of Input can be set up to90 ofEndvalueofInput Pressing the Down key will enter the New Change Start valueofInputedit mode Pressing Up key will confirm the present value as S...

Страница 23: ...l advance the operation to the next digitandsetthethirddigit in thiscaseto 5 Enter New Change Start value of Input third digit entered prompting for fourth digit denotes that digit will be flashing Pr...

Страница 24: ...llthevaluebetweenyes no YES Elbowfunctionisenabled no Elbowfunctionisdisabled Pressing Up key will accept the displayed condition and advance to the Elbow value of Input selection section 3 1 5 4 orOu...

Страница 25: ...ing Up key will confirm the present value as Elbow valueof the Input and advance to the Output parameter setting section3 1 6 New Change Elbow value of theInput Denotes that digit will be flashing Pre...

Страница 26: ...ingforfourthdigit denotesthatdigitwillbeflashing Pressing the Down key will scroll the value of the fourth digit from 0 through to 9 the value will wrap from 9 round to 0 depending onsetvalueofEndvalu...

Страница 27: ...nd advance to the StartvalueofOutput1 section3 1 6 1 2 3 1 6 1 2 Startvalueofoutput1 This screen allows the user to set the Start value of Output 1 considerdasDCCurrent StartvalueofOutputcanbeset upto...

Страница 28: ...y will scroll the value of the second digit from 0 through to 4 the value will wrap from 4 round to 0 depending on the set End valueofOutput Pressingthe Up keywill advance the operation to the nextdig...

Страница 29: ...utput Pressing the Up key will advance the operation to the New Changed Start value of the Output 1 and set the fourth digit inthiscaseto 0 3 1 6 1 3 Elbowvalueofoutput1 New changedStartvalueoftheOutp...

Страница 30: ...Denotes that digit will be flashing Pressing the Down key will scroll the value of the first digit from 0 through to 1 the value will wrapfrom1roundto0depending onthesetEndvalueofOutput Pressing the U...

Страница 31: ...round to 0 depending on the set End value of Output Pressing the Up key will advancetheoperationtothenext digit and set the third digit in this caseto 0 Enter New Change Elbow value of the Output 1 t...

Страница 32: ...screen allows the user to set the End value of Output2 consideredasDCVoltage TheEndvalueofVoltageOutputfixedat10V Pressing the Down value remains constant because End valueisfixed Pressing Up key will...

Страница 33: ...it itis always0 Pressingthe Up keywill advancetheoperationtothenext digitandsetthefirstdigit inevery caseto 0 Enter New Change Start value of the Output 2 first digit entered promptingforseconddigit D...

Страница 34: ...otes that digit will be flashing Pressing the Down key will scroll the value of the fourth digit from0throughto9 thevaluewillwrapfrom9roundto0 Pressing the Up key will advance the operation to the New...

Страница 35: ...he Output 2andexitsetupmenu Denotes that digit will be flashing Pressing the Down key will scroll the value of the first digit from 0 through to 1 the value will wrap from 1 round to 0 depending these...

Страница 36: ...endingthesetEndvalueofOutput Pressing the Up key will advance the operation to the nextdigitandsetthethirddigit inthiscaseto 0 Enter New Change Elbow value of the Output 2 third digit entered promptin...

Страница 37: ...are are required to programthetransducer Details of the programming cable and the software are to befoundinthe separateDatasheet PRKAB601Le Theconnectionsbetween PCPRKAB601Transducer The power supply...

Страница 38: ...Transducer output type can be changed from DC current to DC voltage depending upon user requirement on site To change output type user has to set the transducer output type parameter either to voltag...

Страница 39: ...refer Modbus Rs485 section Note If DIP switch setting is done first and then output type parameter is configured using either of the above three methods then switch OFF ON the Transducer For changing...

Страница 40: ...put Insert the front cover 1234 ON 1234 ON Insert the front cover press in direction of arrow Switches of Output 2 can be set for desired OutputtypeVoltageorCurrent Switches of Output 1 can be set for...

Страница 41: ...g the Back cover transducer can be used for required application Insert the Interface card PCB and Back cover press in directionofarrow 39 6 After inserting the front cover insert the Interface card P...

Страница 42: ...the line The cable should be terminated at each end with a 120 ohm 1 4 Wattmin resistor RS 485 network supports maximum length of 1 2km Including the Master a maximum of 32 instruments can be connecte...

Страница 43: ...h contains some other error e g Attempt to set floating point variable to an invalid value The response generated will be Function code ORed with HEX 80H Theexceptioncodesarelistedbelow Format of Data...

Страница 44: ...reading the data must be restricted to 20 parameters or less Exceeding the 20 parameter limit will causeaModBusexceptioncodetobereturned Query 01 Hex 04 Hex 00 Hex 00 Hex 00 Hex 02 Hex 71 Hex CB Hex...

Страница 45: ...register Most significant 8 bits of Data 1 High Byte register 1 of the parameter requested Data register Least significant 8 bits of Data 1 Low Byte register 1 of the parameter requested Data registe...

Страница 46: ...evice Address Function Code Start Address High Start Address Low Number of Registers Hi Number of Registers Lo CRC Low CRC High 01 Hex 03 Hex 00 Hex 0E Hex 00 Hex 02 Hex A5 Hex C8 Hex Address Register...

Страница 47: ...ted Dataregister Most significant8bitsofDataregister 2HighByte 2oftheparameter requested Dataregister Leastsignificant8bitsofDataregister 2LowByte 2oftheparameter requested Note Two consecutive 16 bit...

Страница 48: ...er 2 High Byte Data Register 1High Byte 46 Byte Count Total number of data bytes received Dataregister Most significant8bitsofDataregister 1HighByte 1oftheparameter requested Dataregister Leastsignifi...

Страница 49: ...00 22 18 Analog O P Type 2 00 R Wp 1 00 02 00 3 2 Mode selection 19 00 9 00 10 Device address RS 485 Setup 10 0E 12 R Wp R Wp R Wp 40039 Address Register 40007 40009 40011 40019 40015 40021 40023 4002...

Страница 50: ...dress is used to set the simulation OutputAto 10 of Output by writing 1000 and100 ofOutputbywriting10000 This address is used to set the Analog O P Type 1 as Voltage Current Voltage 1 Current 2 This a...

Страница 51: ...ure conforms to IP 40 The terminals of the product shouldbeprotectedfromliquids The can be mounted either on a top hat rail or directly on to a wall or a mounting plate 19200 NONE 19200 ODD EVEN 19200...

Страница 52: ...s unit Ensure that all suppliesarede energisedbeforeattemptingany connectionordisconnection 3 These products do not have internal fuses therefore external fuses must be used to ensure safety under 5 1...

Страница 53: ...source Theunithasbeendesignedtoautomatically recover in the event of a high level of transients In extreme circumstances it may be necessary to temporarily disconnect the auxiliary supply for a period...

Страница 54: ...circuit may 5 5 Fusing Itisrecommendedthatallvoltagelinesarefittedwith1ampHRC fuses 5 6 Earth GroundConnections For safety reasons CT secondary connections should be groundedinaccordancewithlocalregu...

Страница 55: ...consumption Measuring Output Y Single or Optional Dual Output type Load independent DC Voltage or DC Current Onsite selectable through DIP switches Programming Loadindependent 0 20mA 4 20mA OR DC out...

Страница 56: ...or Current Basic Accuracy 0 2 C Factor C The Highest value applies C Y1 Y0 X2 X1 X0 Y2 or C 1 C Y1 Y2 X1 X2 1 1 or C 1 Y0 Y2 X0 X2 1 1 or C 1 C Linear characteristics Bent characteristics For X1 X X2...

Страница 57: ...Y0 X0 Y2 X2 Y X Y0 X0 Y2 X2 Output characteristics 1 Example of setting with Linear characteristics X0 Start value of input Y0 Start value of output X1 Elbow value of input Y1 Elbow value of output X2...

Страница 58: ...Rated Value Auxiliary supply frequency Rated Value Output Load Rn 7 5 V Y2 1 With DC current output signal Rn Y2 1 mA 1 With DC Voltage output signal Miscellaneous Acc to IEC EN 60688 Additional Erro...

Страница 59: ...Class V 0 acc To UL 94 selfextinguishing nondripping free of halogen Mountingposition Railmounting wallmounting Weight Approx 0 4kg ConnectionTerminal ConnectionElement ConventionalScrewtypeterminal w...

Страница 60: ...of cycles 10 in each of the three axes EN 60 068 2 7 Shock Acceleration 3 x 50g 3 shocks in each direction EN 60 068 2 1 2 3 Cold Dry Damp heat IEC 61000 4 2 3 4 5 6 IEC 61326 Electromagnetic compatib...

Страница 61: ...59...

Страница 62: ...n the instrument Warning concerning a point of danger Attention observe documentation Equipment protected throught by Double insulation or reinforced insulation DC voltage Current AC DC voltage 3 7 Is...

Страница 63: ...61 Notes...

Страница 64: ...62 Notes...

Страница 65: ...63 Notes...

Страница 66: ...nufacturer has no control over the field condition which influence product installation It is the user s responsibility to determine the suitability of the installation method in the user s field cond...

Страница 67: ...65 Notes...

Страница 68: ...INSTRUMENTS Measure Control Record with a Difference F 31 M I D C Satpur Nashik 422 007 India Tel 91 253 2202162 2202202 Fax 91 253 2351064 Email marketing rishabh co in www rishabh co in RISHABH INS...

Отзывы: