Chapter 6. Setting via Telnet
6-7
Command
Default
Description
setup serial 1 rport
<socket number>
4000
Specify the number of the target port to be connected in TCP Client
mode.
setup serial 1 alive
<0 ~ 32767>
0
Disconnect the socket connection if the specified time is passed
without any communication after the sock is connected to a server.
setup serial 1 mtu
<1 ~ 1100>
1
MTU is the abbreviation of Maximum Transmission Unit and is set
to transmit continuous data from the corresponding port at a time.
setup serial 1 login
[enable / disable]
Disable
In TCP Server mode, check the user name and the password when
a client attempts to connect.
setup serial 1
username
<username>
conuser
In TCP Server mode, set the user name to request for a clients’
connection (up to 32 bytes).
This command is only applied to the use of the port login function.
setup serial 1
password
<password>
99999999
In TCP Server mode, set the password to request for a client’s
connection (up to 32 bytes).
This command is only applied to the use of the port login function.