6
Automatic charging current limits
Y
ou can set the upper limit for the charging current when charging your NiCd or NiMH batteries; It is useful for NiMH
batteries of low impedance and capacity in the “AUTO” charging mode.
Capacity limit
The charging capacity is always calculated as the charging current multiplied by the time. If the charging capacity
exceeds the limit, the process will be terminated automatically. You can set the maximum value.
Temperature threshold*
The batteries internal chemical reaction can cause the temperature of the battery to rise. If the temperature limit is
reached, the process will be terminated. *This function is available by connecting an optional temperature probe,
which is not included.
Processing time limit
You can limit the maximum total process time to avoid any possible unwanted damage to the battery if detecting
errors are unusual.
Input power monitoring
To protect a car battery used as DC input power from being damaged, its voltage is constantly monitored.
If it drops below the lower limit, the process will end automatically.
Data store / load
A maximum of five batteries data can be stored for the users convenience. You can keep the data
pertaining to each program setting of the battery for continuous charging or discharging. Users can
use these stored data settings at any time without any special program setting.
Cyclic Charging/Discharging
1 to 5 cyclic and continuous process of charge>discharge or discharge>charge is operable for battery refreshing
and balancing (NiCd & NiMH only).