Operator Manual Rev 2.01
L003-507-V1.2.1
Page 9
Setting Dynamic Scale Factor
1.5 Dynamic Scale
With the scale at zero the dynamic scale factor can now be set. The reference weight of
a fully loaded truck should be obtained at a nearby certified truck scale. Simply drive
across the axleWEIGHr to capture a truck’s total weight.
(See also page 20-21)
CAPTURED TOTAL ON BOTTOM:
Divide the average of 4 to 5 weighments using this formula:
K/R=D
K = Known weight of truck (reference)
R = Average reading of 5 weighments from axleWEIGHr axle scale
D = Dynamic Scale Adjustment
1. Press and hold [F2] for
2 seconds
to enter the configuration menu.
2. The lower display will show:
“DISCARD”.
3. Use the [UP] [DOWN] arrow keys to scroll to “DYN.SCL”. Press [OK] to show
INBOUND*. Press [OK] to change current value: 1.000000.
4. Enter your Dynamic factor up to 6 decimal places. X.XXXXXX and press [OK].
5. Use the [UP] [DOWN] arrow keys until “QUIT” then press [OK] to exit.
If your configuration does not have directional sensors please use INBOUND setting only.