background image

Operator Manual Rev 2.01 

Page 26 

AXLE-613-201

 

Clicker: Small black key fob used for remote id of trucks 

Power Supply: 120 VAC Power supply located inside the enclosure near the M12 
connectors (see figure 1) 

 

 

 

SPECIAL SETTINGS MENU: 

 Press and Hold Power & F1 together at the same time. This will enter a special 
settings menu and should only be done by qualified personnel. 

The SEL.TYPE option allows the farm/field selection to be switched from global 
(all trucks assigned) to multiple (each truck is assigned) to a single farm and 
field. 

 

Press OK Key to enter Menu 

 

Use up/down arrow keys to switch from GLOBAL to MULTIPLE 

Press OK to make Selections and then arrow keys to QUIT 

MASSBIND: 

 This Menu allows the pairing of all key fobs in the truckDB file –  

 

Enter the Special settings menu and use arrow keys to navigate to MASSBIND 

 Press OK to begin key pairing – all keys fobs will need to be pressed in order #1, 
#2 etc. until all key fobs have been paired. 

  DONE will be displayed after each successful key bind and then the next ID will 
be displayed along with the message Press Clicker #  

Содержание axleWEIGHr

Страница 1: ...L003 507 Reference Manual...

Страница 2: ...in order to improve design performance or reliability The information in this manual is believed to be accurate in all respects at the time of publication but is subject to change without notice Rins...

Страница 3: ...13 Dynamic Scale Creating Setting up Trucks 9 1 14 Setting Time Date 10 1 15 Stability 11 1 16 Traffic Lights 12 1 17 Clicker Operation 13 1 18 USB Operation 14 1 19 Printer Operation 2 SETTING UP TRU...

Страница 4: ...cific application The discard timer allows for weighing first then setting up the truck id The farm configuration data can be setup to individual trucks for unique data basing options Many of the feat...

Страница 5: ...Operator Manual Rev 2 01 L003 507 V1 2 1 Page 3 User Interface and Display Code Description 1 Display 2 Numeric Keypad 3 Function Keys Fixed 4 Power Key...

Страница 6: ...function not available 8 Secondary Display totalised weight of last truck 1 6 Primary Annunciators Symbol Name Description HOLD Visible when the displayed reading is held NET Visible when the displaye...

Страница 7: ...s most useful where strings are small and contain no lowercase or unprintable characters The available characters are printed in orange on the keypad Code Description 1 Number Buttons 0 9 short press...

Страница 8: ...pt changes and finish Long press of cancel Cancel and exit without changes Cancel Delete character Up Down Move cursor Long press of down Delete string after cursor Switch editing modes 1 9 Turn Instr...

Страница 9: ...shown below 110 VAC 240 VAC accepted AC POWER MAIN CONNECTIONS Grey Terminal Black HOT Connector 1 Scale Cable 5 pin White Terminal White Neutral Connector 2 Remote Display Green Terminal Green Groun...

Страница 10: ...13 201 1 12 Zero Key When an empty scale has drifted away from a true zero reading this key is used to perform a zero adjustment on the scale display The zero adjustment is stored when power is remove...

Страница 11: ...eighments using this formula K R D K Known weight of truck reference R Average reading of 5 weighments from axleWEIGHr axle scale D Dynamic Scale Adjustment 1 Press and hold F2 for 2 seconds to enter...

Страница 12: ...weight if one pass Farm Field selection will then prompt see section 2 10 2 Editing Truck Data existing Select the truck you want to configure Proceed through the rest of the prompts Press cancel key...

Страница 13: ...trucks in the truck database Alternately use the key fob Setting up Farm Field F1 These options are associated with the Truck key and allow different fields to be assigned to different trucks Note If...

Страница 14: ...Lights While at Zero stable weight the traffic lights should both be off There are various conditions that will activate the lights If there are errors the RED light will activate See table below TRA...

Страница 15: ...Config menu Long press of F2 and go to KEY BIND menu Press OK to enter learn mode Once key fob has been press DONE will display Weigh in 2 PASS Weigh out pre set tare 1 PASS Weigh out 2 PASS These ar...

Страница 16: ...al log file will remain on the console FROM USB This means you will duplicate the files from the USB drive If you have modified the truck csv file or the harvest csv file then they will overwrite your...

Страница 17: ...01 L003 507 V1 2 1 Page 15 Ensure tension spring is configured for maximum tension as shown above to ensure optimal printing operation There is a PRINT test button shown in figure above used to perfo...

Страница 18: ...ight mode The Cancel key C or OK key allows you to cancel out of the weigh out mode and return to normal mode without clearing the first weight or adding any weight to totals 1 22 Weighing first then...

Страница 19: ...Operator Manual Rev 2 01 L003 507 V1 2 1 Page 17...

Страница 20: ...settings TRUCK F1 A short press of the truck button will allow you to select from your list of permanent trucks Use the arrow keys to select truck Short press select of truck Long press configure tru...

Страница 21: ...Operator Manual Rev 2 01 L003 507 V1 2 1 Page 19 To re bind all wireless key fobs or to change the farm field selection methods see end of manual...

Страница 22: ...This information should be setup and edited as new farms fields are added or removed These should all be typed in capital letters The R423 display is optimal with upper case lettering Description Map...

Страница 23: ...ble Id Truck Column Id and truck needs to unique and will display to the R423 screen print on the ticket The id number should be sequential and in order Example 1 2 3 4 etc The labels in the truck col...

Страница 24: ...e log csv file contains all of the weight data for each truck including the farm and field configuration A farm field that does not have data details is due to the farm field not configured The truck...

Страница 25: ...AD The weight is above the maximum allowable weight reading Warning overloading may damage mechanical scale elements Check the condition of load cell connections Check for damaged load cell ERROR RANG...

Страница 26: ...scaling factor for in motion calibration adjust Zero zero calibration capture do not use Span span calibration capture do not use MvV raw millivolt reading from scale base example 2234 0001 Note to e...

Страница 27: ...423 instrument and up to the entire axleWEIGHr box including kiosk printer R423 This is the stainless indicator mounted on the front of the axleWEIGHr LUA The lua module is located on the back of the...

Страница 28: ...om global all trucks assigned to multiple each truck is assigned to a single farm and field Press OK Key to enter Menu Use up down arrow keys to switch from GLOBAL to MULTIPLE Press OK to make Selecti...

Страница 29: ...Notes...

Страница 30: ......