Symmetry Maintenance Instructions 11699-B 02-12
|
17
RDV3611/10 flue configurations
Min. 0.9 m
3.0 m
Max. 5.4 m
Max. 1.8 m
4.2 m
1.8 m
No restrictor
Restrictor position # 2
Restrictor position # 3
Restrictor position # 4
Min. 0.9 m
4.2 m
Max. 5.4m
Max. 3.5 m
Restrictor position # 2
1.8 m
3.0 m
Restrictor position # 3
Restrictor position # 4
No restrictor
Min. 0.6 m
after bend
Min. 0.9 m
2.4 m
4.2 m
Max. 5.4 m
Min. 0.3 m
Max. 3.5 m
Max. 0.9 m
Max. Horizontal =(6.03-Vertical)/0.52
Max. Horizontal = Vertical/0.692
Max. 1.2 m
No restrictor
Restrictor position # 3
Restrictor position # 4
Vertical termination with
45 ° bends
Vertical termination with 90 ° bends
Horizontal termination with a
90 ° bend
1
2
4
3
1
2
4
3
Flue restrictor positioning