manualshive.com logo in svg
background image

WOOD INSTALLATION TO COMPLY WITH AS/NZS2918:2001

GAS INSTALLATION TO COMPLY WITH NZS5261:2003

Jetmaster existing chimney 

installation instructions - WooD / gas

7/2013

imPortant: read all instructions carefully before starting installation. Failure to  

follow these instructions may result in a fire hazard and will void the warranty.

4.R.1A

Содержание Jetmaster Wood

Страница 1: ... TO COMPLY WITH NZS5261 2003 Jetmaster existing chimney installation instructions WOOD GAS 7 2013 IMPORTANT Read all instructions carefully before starting installation Failure to follow these instructions may result in a fire hazard and will void the warranty 4 R 1A ...

Страница 2: ...500 600 550 350 650 630 600 600 700 650 350 650 630 700 SH 700 800 750 350 650 630 700 SH L 700 800 750 350 600 580 700 D 700 800 750 400 700 680 850 L 850 950 900 450 700 680 1050 1050 1150 1100 500 800 780 1050 LL 1050 1150 1100 500 700 680 Table 1 Solid Fuel Box Dimensions Dimensions in mm Dimensions in mm MODEL NG LPG 700 SFB 45 38 850 SFB 50 43 1050 SFB 65 65 Table 3 Gas Tray MJ Hr Ratings 4 ...

Страница 3: ...re fitting the firebox to ensure a smooth passage for the smoke gas emissions is in place Final plastering shaping work will be required once the firebox is fitted into place Line the back face and sides of the opening with Rockwool before sliding the firebox into position There must be a tight seal between the firebox and the sides and rear of the chimney using Rockwool Always ensure that the bot...

Страница 4: ...tar demolish and clean Solid bricks and or Hebel block plastered or glue together opening width maybe increased to suit Fig 2 Plan View Step 3 min 25 min 25 do not block chimney ports Fig 3 Drawing Not To Scale Drawing Not To Scale Drawing Not To Scale ...

Страница 5: ... mortar top back sides of firebox Solid bricks and or Hebel block plastered or glued together Rock wool to seal Lintel do not block chimney ports Maintain the air intake unobstructed Floor protector extension if necessary heat sensitive floor min 4600mm Drawing Not To Scale Tested to AS NZS 2918 2001 Appendix E ...

Страница 6: ...50 450 75 850 L 1250 450 75 1050 LL 1450 600 75 Gas Models 700 1100 300 850 1250 300 1050 1450 300 A B Dimensions in mm Table 4 Clearances to Combustible Mantels X Y 1 2 Notes 1 Mantel Surround 2 Tile or margin facing non com bustible material X see Fig 7 Y See Fig 7 Refer to Fig 8 for Side Clearances Fig 6 A minimum 75mm thickness refers only to Hebel Block Minimum 100mm thickness required if pou...

Страница 7: ...nces to Combustible Mantels min 300 100 min 100 min min 25 min 25 Surround Leg 4 5 Combustible Side Wall max recess 100mm 4 5 Fig 8 Drawing Not To Scale 0 25 45 50 90 100 150 170 200 250 300 350 100 200 300 400 500 230 320 380 425 460 483 X Y Mantel Surround projection from wall Top Clearance mm Height from top of firebox to underside of mantel surround Projection mm Combustible Materials Non Comb...

Страница 8: ...ATED WOOD AS A FUEL CAN BE HAZARDOUS 4 R 1H MODEL MINIMUM VENT SIZE x2 Square Design L x H Rectangle Design L x H 440 700 100 x 100 200 x 50 850 125 x 100 250 x 50 1050 150 x 100 250 x 100 The Fireplace Ltd recommends that allowances are made for air replacement vents to be located near the fireplace to aid combustion and reduce the incidence of back venting Refer to Table 5 for air vent sizing an...

Отзывы: