HEATER LOCATION
When positioning the heater the main variables governing the location are Flueing and Warm Air Distribution.
This heater must not be installed where curtains or other combustible materials could come into contact with it. In
some cases curtains may need restraining.
ENCLOSURE REQUIREMENTS
These Rinnai units have a cool outer casing allowing it to be installed into existing Masonry fireplace or into a
decorative fireplace constructed from combustible materials such as wood or plaster.
A pair of wheels located at the rear the heater
allows it to slide in and out of the enclosure for ease
of commissioning and maintenance. As such the
heater must be positioned on a flat and level
surface that allows free movement.
In a masonry fireplace, use a slurry of sand and
cement to level the base as required.
In a decorative fireplace, if the appliance is
elevated from the ground, a base must be
constructed using a board with supporting joists as
shown. The joists used to support the appliance off
the ground
MUST BE
capable of supporting a
minimum of 105 kg.
WALL PENETRATION REQUIREMENTS
Mark the location of the gas supply (consumer piping) and flue pipe
penetrations from the centreline
of the heater enclosure using the
following dimensions:
Consideration must be given to the position of any studs, noggins or other
components of the wall structure.
For all installations, ONLY Rinnai ASP & ES Flue components MUST BE used. The Rinnai RHFE-
952ER & RHFE-1252ER units MUST NOT be flued into ‘natural draft’ flue system or via a chimney.
Consult the Rinnai “Power Flued Flamefire Space Heater Co-axial Flue System Installation Manual”
supplied with flue kits ASPDFK or ASPKIT03 for detailed flue installation instructions.
Enclosure Dimensions
RHFE-952ER
RHFE-1252ER
Width
965 mm to 980 mm
1265 mm to 1280 mm
Height
570 mm to 580 mm
570 mm to 580 mm
Depth
570 mm (minimum)
The enclosure dimensions specified are critical to the
successful installation of this appliance and must be strictly
adhered to.
RHFE-952ER
RHFE-1252ER
Centreline of enclosure
Centreline of enclosure
420 mm left of centreline
570 mm left of centreline
65 mm from base of enclosure
65 mm from base of enclosure
430 mm right of centreline
580 mm right of centreline
500 mm from base of enclosure plus or minus 25mm
Ensure the penetration points are marked accurately as this is critical for successful appliance
installation.
The penetration for the flue pipe only needs to be made for ‘Direct’ flue installations, where the flue
terminal is located directly to the rear of the appliance.
If no flue pipe penetration is required the markings are still useful for indicating the correct
position of the flue transition within the enclosure for extended horizontal flue applications.
WARNING
JOIST
JOIST
#
850mm
(for RHFE-952ER)
1030mm
(for RHFE-1252ER)
RIGHT
WHEEL
LEFT
WHEEL
RIGHT
WHEEL
LEFT
WHEEL
‡ MDF (Customwood) board Minimum 20mm
#
Please Note: there is a third wheel in the centre for the RHFE-1252ER
‡
w
d
h
w
h
d
NOTE
Ø 100
5
4
1
2
3
Gas supply penetration
Flue pipe penetration
1
1
1
2
2
4
4
5
NOTE