CARE AND MAINTENANCE
Your Rinnai appliance is also fitted with self diagnostic electronics that monitor the appliance during start-up and
operation.
Should a fault occur the appliance will then shut down, the fault that has caused the shut down will be indicated by
a pair of flashing digits in the error display window
, which is located behind the fascia and can be viewed by
looking through the of the return air vent
.
Refer to the table below for probable cause and the suggested remedy.
Code
Probable Cause
Suggested Remedy
00
Mains power failure
Interruption to the power or gas supply will turn your heater off and a
restart will be required. This is a safety feature designed to ensure
that un-attended starts do not occur after power or gas interruptions.
Access the 'Push Button Control Panel'
. This is located on the
front of the heater at the lower right hand corner.
Press ON / OFF button
twice, after which you will be able to hear
the ignition sparking and the heater will restart and return to normal
operation, after 30 seconds of operation the remote control may then
be used to select the desired flame height and fan speed.
11
Ignition failure
Check gas supply is turned on, switch the heater to Standby and then
On again.
If the error persists a service call will be required.
12
Incomplete combustion
Check gas supply is turned on, switch the heater to Standby and then
On again.
If the error persists contact Rinnai.
14
Inlet Blockage / Overheat
Clean inlets,
if the error persists a service call will be required.
16
Room overheat
Lower room temp to below 40°C.
31
Room temperature sensor faulty
A service call will be required.
32
Overheat temperature sensor faulty
A service call will be required.
33
Overheat temperature sensor faulty
A service call will be required.
53
Spark sensor faulty
A service call will be required.
61
Combustion fan motor faulty
A service call will be required.
71
Solenoids faulty
A service call will be required.
72
Flame detection circuit fault
A service call will be required.
73
Communication error
A service call will be required.