Maintenance Codes
55
Code
Definition
Remedy
16
Over temperature
warning (safety
shutdown because
unit is too hot).
Check for restrictions in air flow around the unit and vent termination.
Licensed
professional
only
Check for foreign materials in combustion chamber and/or exhaust piping.
Check for clogged heat exchanger.
Check that the gas type being used is correct for the unit.
30
FV sensor
(flammable vapor)
Licensed
professional
only
Check sensor wiring for damage.
Measure resistance of sensor.
Replace sensor.
31
Burner Sensor.
32
Heat exchanger
outgoing temp.
thermistor.
Licensed
professional
only
Check sensor wiring for damage.
Measure resistance of sensor.
Clean sensor of scale buildup.
Replace sensor.
35
Tank temperature
thermistor.
Licensed
professional
only
Check sensor wiring for damage.
Measure resistance of sensor.
Verify that sensor is properly mounted on the tank surface.
Replace sensor.
Содержание RH180
Страница 1: ...Rinnai RH180 Hybrid Tank Tankless Water Heater Installation Fundamentals Level II 1...
Страница 3: ...3 RH180 Hybrid Tank Tankless Water Heater Level II Training Program Installation Fundamentals...
Страница 6: ...RH180 Sequence of Operation 6...
Страница 8: ...RH180 Water Heater Sizing 8...
Страница 10: ...RH180 Product Features Safety devices 10...
Страница 18: ...Dimensions 18...
Страница 38: ...RH180 Temperature Controller 38...
Страница 39: ...Temperature Controller 39...
Страница 41: ...RH180 Maintenance and Warranty 41...
Страница 49: ...Component Description 49...
Страница 50: ...Component Description 50...
Страница 61: ...RH180 FAQ 61...
Страница 64: ...RH180 Residential Applications 64...
Страница 70: ...70 This concludes the RH180 Water Heater Training Program Level II Installation Fundamentals 401102 12 2013...