RH180 Sizing
Water Heating
Options
Max input (Btuh
/ Kwh)
Tank Capacity
(gal.)
Time of available
hot water (min.)
Time of available
hot water (min.)
Recovery time
(min.)
Showers In use
at one time
70⁰ temp rise
70⁰ temp rise
70⁰ temp rise
Electric Tank
4.5 Kw
40
21
10
88
Gas Tank
34,000 Btu
40
18
8
36
40,000 Btu
50
26
11
40
75,000 Btu
75
50
19
32
Rinnai RH180
Hybrid
Tank -Tankless
91,300 Btu
40
Continuous
11
16
Rinnai Tankless
Up to 199,000
Btu
N/A
Continuous
Continuous
N/A
•
Data is based on a 50⁰F inlet water temperature and a 120⁰F hot water set point (70⁰F rise).
•
Shower heads assumed to be 2.5 gpm mixed flow rate with 105⁰F at the fixture.
•
Available hot water time and recovery time based on industry standard calculation methods
and Rinnai lab testing. Actual results may vary based on the application.
Содержание RH180
Страница 1: ...Rinnai RH180 Hybrid Tank Tankless Water Heater Installation Fundamentals Level II 1...
Страница 3: ...3 RH180 Hybrid Tank Tankless Water Heater Level II Training Program Installation Fundamentals...
Страница 6: ...RH180 Sequence of Operation 6...
Страница 8: ...RH180 Water Heater Sizing 8...
Страница 10: ...RH180 Product Features Safety devices 10...
Страница 18: ...Dimensions 18...
Страница 38: ...RH180 Temperature Controller 38...
Страница 39: ...Temperature Controller 39...
Страница 41: ...RH180 Maintenance and Warranty 41...
Страница 49: ...Component Description 49...
Страница 50: ...Component Description 50...
Страница 61: ...RH180 FAQ 61...
Страница 64: ...RH180 Residential Applications 64...
Страница 70: ...70 This concludes the RH180 Water Heater Training Program Level II Installation Fundamentals 401102 12 2013...