Maintenance Codes
Maintenance codes flash on the temperature controller when a fault occurs.
Depending on the code, water flow or power may need to be reset to clear the code.
See owner's manual for a full detailed list of all codes.
51
Diagnostic Codes and Remedies
Some of the checks below should be performed by a licensed professional. Consumers
should never attempt any action that they are not qualified to perform.
Code
Definition
Remedy
05
Air Filter Error.
Follow the procedure “Air Screen Inspection, Detection and Cleaning” in the
operation / installation manual. If the error code continues to flash after
cleaning the air filter, review the items under “Code 10 ” or contact a qualified
service technician.
NOTE: This code will allow the water heater to continue operating.
07
Circulation flow
rate has dropped
below 2.1 GPM.
Check the water filter for blockage.
Check pump operation and wiring.
Clean heat exchanger.
NOTE: This code will allow the water heater to continue operating.
10
Air supply or
exhaust blockage.
Check that nothing is blocking the vent, inlet screen or “Combustion Air
Assembly”.
Check all vent components for proper connection.
Содержание RH180
Страница 1: ...Rinnai RH180 Hybrid Tank Tankless Water Heater Installation Fundamentals Level II 1...
Страница 3: ...3 RH180 Hybrid Tank Tankless Water Heater Level II Training Program Installation Fundamentals...
Страница 6: ...RH180 Sequence of Operation 6...
Страница 8: ...RH180 Water Heater Sizing 8...
Страница 10: ...RH180 Product Features Safety devices 10...
Страница 18: ...Dimensions 18...
Страница 38: ...RH180 Temperature Controller 38...
Страница 39: ...Temperature Controller 39...
Страница 41: ...RH180 Maintenance and Warranty 41...
Страница 49: ...Component Description 49...
Страница 50: ...Component Description 50...
Страница 61: ...RH180 FAQ 61...
Страница 64: ...RH180 Residential Applications 64...
Страница 70: ...70 This concludes the RH180 Water Heater Training Program Level II Installation Fundamentals 401102 12 2013...