Maintenance - Tank
44
• Drain the water from the tank at least once per year. This will remove excess
sediment from the bottom of the tank. Accumulated sediment will reduce the
efficiency and life expectancy of the tank.
• Manually operate the relief valve at least once per year.
• The water heater is equipped with an anode rod that is designed to prolong the
life of the glass-lined tank. This anode is slowly consumed protecting the tank
from corrosion. The anode should be checked every two years. If more than
half of the anode has been consumed it should be replaced.
• In certain conditions, the anode rod can react with the water producing
discolored water or an odor. This can be a result of the reaction between the
anode and hydrogen sulfide gas dissolved in the water. For more information
see the “required maintenance” section of the operation and installation manual
under “Anode”.
Содержание RH180
Страница 1: ...Rinnai RH180 Hybrid Tank Tankless Water Heater Installation Fundamentals Level II 1...
Страница 3: ...3 RH180 Hybrid Tank Tankless Water Heater Level II Training Program Installation Fundamentals...
Страница 6: ...RH180 Sequence of Operation 6...
Страница 8: ...RH180 Water Heater Sizing 8...
Страница 10: ...RH180 Product Features Safety devices 10...
Страница 18: ...Dimensions 18...
Страница 38: ...RH180 Temperature Controller 38...
Страница 39: ...Temperature Controller 39...
Страница 41: ...RH180 Maintenance and Warranty 41...
Страница 49: ...Component Description 49...
Страница 50: ...Component Description 50...
Страница 61: ...RH180 FAQ 61...
Страница 64: ...RH180 Residential Applications 64...
Страница 70: ...70 This concludes the RH180 Water Heater Training Program Level II Installation Fundamentals 401102 12 2013...