Rinnai 20
RF1800 OIM
FINAL CHECKS
Check that the appliance operates properly making sure that all the supplied parts are used and properly installed.
It is important that the customer is fully aware of how to operate the appliance properly and safely. Advise the
customer to fully read the operation sections of this manual to understand how to get the best out of their appliance.
Advise the customer of the need for regular servicing in order to maintain the warranty.
Complete the
Commissioning Checklist
.
TROUBLE SHOOTING
Symptom
Possible Cause(s)
Owner Actions
Installer Actions
Appliance does
not start
(no spark noise)
Mains power disconnected
→
Check mains supply and isolating switch are ‘On’
Gas control locked out
→
Switch ‘Off’ and ‘On’ again *
Faulty spark electrode
Service call
Check HT lead
Check Electrode is not touching the bracket
Power fuse blown
Service call
Replace fuse
Appliance is sparking
then stops (no flames)
Air in gas pipe
Service call
Purge gas pipes *
Gas supply turned off/empty
→
Turn on gas supply or change bottles *
Flame starts but spark
keeps going
Faulty flame rod
Service call
Check flame rod lead
Check flame rod is not touching the bracket
Wind blowing on burner
→
Prevent excessive draft on burner
Flame starts but
then goes out
Faulty flame rod
Service call
Check flame rod lead
Check flame rod is not touching the bracket
Wind blowing on burner
→
Prevent excessive draft on burner
Appliance goes out
Gas supply ‘Off’ or empty
→
Check gas supply or change/replace bottles
Power supply turned off
→
Check power is on
Wind blowing on burner
→
Prevent excessive draft ‘On’ burner
*
If the appliance fails to ignite after four (4) attempts, turn off the power and gas if possible and arrange for a service call or contact
the installer if the unit is newly installed.
→
Owner corrective action is the same as that of an installer, all other corrective actions are for authorised persons only!
COMMISSIONING CHECKLIST
TO BE COMPLETED BY THE INSTALLER
Serial Number
___________________________________________________________
Installers
Name
___________________________________________________________
Installers License No.
___________________________________________________________
Installers Contact No.
___________________________________________________________
Certificate Of Compliance No.
___________________________________________________________
Installation Date
__________/__________/__________
NO
YES
1. Is the appliance positioned in a suitable location with regards to clearances?
2.
Is the unit fixed in location?
3. Have all gas connections been checked for leaks using a soapy water solution?
4. Have you instructed the owner of the correct operation of this appliance before leaving?
5. Have you left the operating instructions with the owner?
6. Have you removed all PVC plastic coating material?
WARNING
Ensure all PVC plastic coating material is removed before operating the unit.
If you have answered NO to any of the above questions you MUST NOT allow the appliance to be
operated until the item has been rectified.