Sensors and Safety Functions
•
Hot Water Delivery Thermistor
: Measures hot water temperature at the outlet valve (i.e. the ‘mixed’
temperature).
•
Flame Rod
: Monitors combustion characteristics inside the combustion chamber. If the flame fails,
gas supply is stopped.
•
Overheat Switch
: Situated on the heat exchanger, gas supply is stopped when water temperature
reaches 97ºC for a number of seconds.
•
Fusible Link
: Situated on the heat exchanger, electrical power supply is stopped if the temperature
exceeds 129ºC.
•
Water Pressure Relief Valve:
Safeguards the water circuit against excessive inlet pressure. Opens at
2060 kPa, closes at 1470 kPa.
•
Electrical Fuse:
(3A glass fuse) prevents against power surges.
•
Surge Protector:
prevents against over-current.
•
Boil Dry Prevention:
If water flow sensor detects no flow, gas supply is stopped.
•
Combustion Fan Speed Sensor
: In case of combustion fan defect (no rotation of fan blades) gas
supply is stopped.
•
Temperature Cutout:
If the delivered hot water temperature rises above the required delivery
temperature for a number of seconds, the gas supply is stopped.
Combustion Specifications
Refer to dataplate on appliance.
Содержание REU-VR2426WS Solar 26
Страница 16: ...REU VR2626WB B26 REU VR2426WS S26 REU VRM2626WG INF26 13 Issue 3 13 11 14 Rinnai 7 Operational Flow Chart...
Страница 50: ...REU VR2626WB B26 REU VR2426WS S26 REU VRM2626WG INF26 46 Issue 3 13 11 14 Rinnai...
Страница 51: ...REU VR2626WB B26 REU VR2426WS S26 REU VRM2626WG INF26 47 Issue 3 13 11 14 Rinnai...
Страница 52: ...REU VR2626WB B26 REU VR2426WS S26 REU VRM2626WG INF26 48 Issue 3 13 11 14 Rinnai...