REU-VR2626WB (B26) /REU-VR2426WS (S26) /REU-VRM2626WG (INF26)
- 29 -
Issue 3 - 13/11/14 ©Rinnai
IMPORTANT
For some areas of dismantling you may need to
isolate any or all of the following:
* Isolate gas supply.
* Disconnect electrical supply from wall socket.
* Isolate water supply.
* Drain
all
water from appliance.
1)
Removal of the
Front Panel
a. Remove four (4) screws.
2)
Removal of the
PCB Unit
a. Remove the front panel. (Refer Item 1.)
b. Remove two (2) PCB unit fixing screws and pull
out forward.
3)
Removal of the
Water Flow Sensor,
Servo and Bypass Servo
a. Remove the front panel. (Refer Item 1.)
b. Remove two (2) screws and locking plates
located on the water supply pipe and bypass
pipe. Pull bypass pipe and water supply pipe
forward to clear servo valves. Ensure O-rings
are not lost or damaged.
4) Removal of the Bypass Servo
(2630 ONLY)
a. Remove two (2) screws from the water flow
servo body, and pull the bypass servo out
forwards. Ensure O-rings are not lost or
damaged.
Содержание REU-VR2426WS Solar 26
Страница 16: ...REU VR2626WB B26 REU VR2426WS S26 REU VRM2626WG INF26 13 Issue 3 13 11 14 Rinnai 7 Operational Flow Chart...
Страница 50: ...REU VR2626WB B26 REU VR2426WS S26 REU VRM2626WG INF26 46 Issue 3 13 11 14 Rinnai...
Страница 51: ...REU VR2626WB B26 REU VR2426WS S26 REU VRM2626WG INF26 47 Issue 3 13 11 14 Rinnai...
Страница 52: ...REU VR2626WB B26 REU VR2426WS S26 REU VRM2626WG INF26 48 Issue 3 13 11 14 Rinnai...