a. the air purifier fan does not begin to rotate.
Is there electrical supply?
1. Confirm the connection at the wall socket.
2. Is the 3 amp fuse blown?
a. The sequence does not continue.
1. Broken wiring or loose pin connectors. (Open circuit)
2. Faulty control panel PCB. (Air Purifier ON/OFF button)
3. Faulty PCB.
4. Loose primary filter. (Error code "05")
b. The air purifier fan does not begin to rotate.
1. Air purifier fan shaft grub screw loose.
2. An obstruction in the air purifier fan is preventing the fan from rotating.
3.
Open circuit or bad connection in motor circuit.
4. Faulty PCB.
YES
Normal Value
AC90~110V
Normal Value
0
(125V.3A)
Ω
Motor Coil Normal Value
60~150
Ω
NO
Содержание RCE-460PTR
Страница 1: ...SERVICE MANUAL RCE 460PTR RCE 560PTR FAN CONVECTOR ...
Страница 16: ...Convector 460 560PTR 11 Rinnai 4 Dimensions Note All dimensions are in millimetres ...
Страница 17: ...Convector 460 560PTR 12 Rinnai 5 Installation The following clearances are recommended for installation ...
Страница 18: ...Convector 460 560PTR 13 Rinnai 6 Schematic Diagram ...
Страница 19: ...Convector 460 560PTR 14 Rinnai 7 Cut Away Diagram ...
Страница 20: ...Convector 460 560PTR 15 Rinnai 8 Operation Principles Control Panel Layout ...
Страница 29: ...Convector 460 560PTR 24 Rinnai ...
Страница 61: ...Convector 460 560PTR 56 Rinnai ...
Страница 62: ...Convector 460 560PTR 57 Rinnai ...
Страница 63: ...Convector 460 560PTR 58 Rinnai ...
Страница 64: ...Convector 460 560PTR 59 Rinnai ...
Страница 65: ...Convector 460 560PTR 60 Rinnai ...
Страница 66: ...Convector 460 560PTR 61 Rinnai ...
Страница 67: ...Convector 460 560PTR 62 Rinnai ...
Страница 68: ...Convector 460 560PTR 63 Rinnai ...
Страница 69: ...Convector 460 560PTR 64 Rinnai ...
Страница 70: ...Convector 460 560PTR 65 Rinnai ...