- 28 -
©Rinnai
Memory Function for Maintenance Data
The 5 most recent error messages and the estimated time of combustion, combustion frequency,
estimated time of air purifier operation, and air purifier operation time are stored, as well as E
2
PROM.
<How to recall data>
While the unit is off, press the “override” and “
∨
” buttons simultaneously for at least 2.5 seconds to
bring up the error history on the display. The error history will display the following in a 2.5 second
cycle : the 5 most recent error messages (the most recent is No. 1; No.5 the oldest), estimated time
of combustion, combustion frequency, estimated time of air purifier operation, and air purifier
operation time.
Example.
<How to Reset> (Same as Initialisation of E
2
PROM)
• While the unit is OFF, press all three buttons “
∧
”, “
∨
”, and “override” simultaneously for at least
2.5 seconds.
• The digital display will go out, and “88:88” will be displayed when resetting has been com-
pleted, then “--:--” will be displayed.
(Additional combustion time, combustion rpm, and additional air purifier operation time will not be
reset.)
Note 1: This operation time will be displayed as the actual operation time after initialisation when
the reset button is pressed.
Item
Digital Display
Comments
Error History
No. 1 (Latest Error)
Sudden Extinction
No. 2
Power Failure
No. 3
Mis-ignition
No. 4
Mis-ignition
No. 5
No error
Combustion Time
1300 hours
Not displayed if below 100 hours
Combustion Frequency
3700 times
Not displayed if below 100 times
Estimated Air Purifier Opera-
tion Time
5000 hours
Not displayed if below 100 hours
Air Purifier Operation Time
Note 1
5000 hours
Not displayed if below 100 hours
Содержание RCE-460PTR
Страница 1: ...SERVICE MANUAL RCE 460PTR RCE 560PTR FAN CONVECTOR ...
Страница 16: ...Convector 460 560PTR 11 Rinnai 4 Dimensions Note All dimensions are in millimetres ...
Страница 17: ...Convector 460 560PTR 12 Rinnai 5 Installation The following clearances are recommended for installation ...
Страница 18: ...Convector 460 560PTR 13 Rinnai 6 Schematic Diagram ...
Страница 19: ...Convector 460 560PTR 14 Rinnai 7 Cut Away Diagram ...
Страница 20: ...Convector 460 560PTR 15 Rinnai 8 Operation Principles Control Panel Layout ...
Страница 29: ...Convector 460 560PTR 24 Rinnai ...
Страница 61: ...Convector 460 560PTR 56 Rinnai ...
Страница 62: ...Convector 460 560PTR 57 Rinnai ...
Страница 63: ...Convector 460 560PTR 58 Rinnai ...
Страница 64: ...Convector 460 560PTR 59 Rinnai ...
Страница 65: ...Convector 460 560PTR 60 Rinnai ...
Страница 66: ...Convector 460 560PTR 61 Rinnai ...
Страница 67: ...Convector 460 560PTR 62 Rinnai ...
Страница 68: ...Convector 460 560PTR 63 Rinnai ...
Страница 69: ...Convector 460 560PTR 64 Rinnai ...
Страница 70: ...Convector 460 560PTR 65 Rinnai ...