Convector 460/560PTR
- 30 -
©Rinnai
The unit will go into Test Mode when the Test Switch is switched ON while the unit is operating.
The unit will go into each of the following modes during Test Mode : Low Pressure Mode, High
Pressure Mode, Decision Level Adjustment Mode, and Sensitive Selection Mode.
• Test Mode...................................................Disables the temperature controls and allows you to
change the level manually. (Cancels when the test
switch is turned on again, or when combustion ceases.)
The level can be raised/lowered with the temperature
control buttons “
∧
” and “
∨
”, however, if they are con-
tinuously pressed for at least 0.5 seconds, it will change
to level 12 or level 1.
• Low Pressure Mode...................................The modulating valve electric current value for low
combustion can be adjusted with the temperature “
∧
”
and “
∨
” buttons. After adjusting, the data will be stored
when Timer 1 is switched ON.
• High Pressure Mode .................................The modulating valve electric current value for high
combustion can be adjusted, with the temperature “
∧
”
and “
∨
” buttons. After adjusting, the data will be stored
when Timer 1 is switched ON.
• Decision Level Adjustment Mode ...........The maximum flame failure detection level can be
adjusted with the temperature “
∨
” button, and the mini-
mum with the temperature “
∧
” button. They can be set
in the following order: 12mV, 14mV, 16mV, 18mV.
After adjusting, the data will be stored when Timer 1 is
switched ON.
• Sensitivity Selection Mode .......................The sensitivity can be changed over from 1 to 2, and
vice versa, with the temperature “
∨
” button. After
adjusting, the data will be stored when Timer 1 is
switched ON. It is factory set at sensitivity level 2.
* To reset each mode, press the ON/OFF button to turn the unit OFF.
* If the Timer 1 button is not pressed during each mode, the updated setting will be cancelled and
the data will not be stored in memory.
* If the data is stored, it will return to test mode and the entered information will be displayed.
Low Pressure Mode
High Pressure Mode
Decision Level
Adjustment Mode
Sensitivity
Selection Mode
Test Mode
Normal OFF
Te
st
Bu
tto
n o
nc
e
Ti
m
er
1
Bu
tto
n
Test Bu
tton two
times
Timer 1
Button
Test Button
three times
Timer 1 Butto
n
Tim
er 1
Bu
tto
n
Te
st B
utto
n fo
ur t
im
es
Test
Button
Содержание RCE-460PTR
Страница 1: ...SERVICE MANUAL RCE 460PTR RCE 560PTR FAN CONVECTOR ...
Страница 16: ...Convector 460 560PTR 11 Rinnai 4 Dimensions Note All dimensions are in millimetres ...
Страница 17: ...Convector 460 560PTR 12 Rinnai 5 Installation The following clearances are recommended for installation ...
Страница 18: ...Convector 460 560PTR 13 Rinnai 6 Schematic Diagram ...
Страница 19: ...Convector 460 560PTR 14 Rinnai 7 Cut Away Diagram ...
Страница 20: ...Convector 460 560PTR 15 Rinnai 8 Operation Principles Control Panel Layout ...
Страница 29: ...Convector 460 560PTR 24 Rinnai ...
Страница 61: ...Convector 460 560PTR 56 Rinnai ...
Страница 62: ...Convector 460 560PTR 57 Rinnai ...
Страница 63: ...Convector 460 560PTR 58 Rinnai ...
Страница 64: ...Convector 460 560PTR 59 Rinnai ...
Страница 65: ...Convector 460 560PTR 60 Rinnai ...
Страница 66: ...Convector 460 560PTR 61 Rinnai ...
Страница 67: ...Convector 460 560PTR 62 Rinnai ...
Страница 68: ...Convector 460 560PTR 63 Rinnai ...
Страница 69: ...Convector 460 560PTR 64 Rinnai ...
Страница 70: ...Convector 460 560PTR 65 Rinnai ...