STANDARD INSTALLATION CONTINUED
Fastening (Collectors to a Metal Roof)
This installation is not suitable for use in cyclonic areas. For further details, please
contact your local Rinnai Solar distributor.
•
Position the lower collector mounting rail
assembly so that the rail is over the roof
purlin and the rail is angled ensure the
collectors have an 8 mm / collector rise.
•
Drill through the roof iron and purlin using
the holes in the rail as a guide. Apply
some silicone sealant down the holes to
ensure no water leakage.
•
Bolt the rail to the roof purlin using a
suitable fastener as shown in
Figure 15
.
Figure 15
- Mount Lower Collector Rail
•
Position the collector(s) onto the roof
above the lower rail. If more than one
collector is being installed, join them
together using the compression fittings
supplied.
•
Push down on the collector retainers to
clamp the collector and tighten the nuts.
•
Place the upper collector mounting rail
above the collectors. Push down on the
collector retainers to clamp the collector
and tighten the nuts.
•
Drill through the roof iron and purlin using
the upper mounting rail as a guide. Apply
some silicone sealant down the holes to
ensure no water leakage and secure with
suitable fasteners as shown in
Figure 16
.
Alternatively the rail can be attached to
the roof using the collector mounting
straps.
Figure 16
- Mount Collector on Roof
Figure 17
- Attach Upper Rail
NOTE
Bolt lower
mounting rail
to roof purlin
using a suitable
fastener
Bolt upper mounting
rail to roof purlin using
a suitable fastener
INSTALLATION OF SOLAR COLLECTORS & CYLINDERS