N-BW2 Networker Bridge (WIFI)
API-N-BW2
Issue 1.3 Page 29 of 48
GROUP2
COMMAND
Values
Description
{“PSU”: {
---
---
Programmed switch on/off operation
“AV”: “$”
W
Y/N
Programming active
Y
= Yes
N
= No
“SW”: “$”
W
F/N
Program to switch off/on
F
= Off
N
= On
“SNT”:
“hh:mm”
W
00-23:00-59
Time to switch on
“SNE”: “$”
W
Y/N
Switch on enabled
Y
= Yes
N
= No
“OP”: “$”
W
M/A
Switched on operating state
M
= Manual
A
= Auto
“PS”: “$”
W
F/N
Switched on pump state
F
= Off
N
= On
“FL”: “##”
W
01 - 16
Switched on fan speed level (01 – 16)
(Manual Operation)
“SP”: “##”
W
19 - 34
Switched on comfort level (Set Point) (19 – 34)
(Auto Operation)
“SFT”:
“hh:mm”
W
00-23:00-59
Time to switch off
“SFE”: “$”
W
Y/N
Switch off enabled
Y
= Yes
N
= No
“ZUUE”: “$”
W
Y/N
Zone U user enabled at switch
on
Y
= Yes
N
= No
“ZAUE”: “$”
W
Y/N
Zone A user enabled at switch
on
Y
= Yes
N
= No
“ZBUE”: “$”
W
Y/N
Zone B user enabled at switch
on
Y
= Yes
N
= No
“ZCUE”: “$”
W
Y/N
Zone C user enabled at switch
on
Y
= Yes
N
= No
“ZDUE”: “$”
W
Y/N
Zone D user enabled at switch
on
Y
= Yes
N
= No
TABLE 4.5a: Networker System {“ECOM”: Group