N-BW2 Networker Bridge (WIFI)
API-N-BW2
Issue 1.3 Page 24 of 48
4.4.1 Single Set Point Operation
In TABLE 4.4.1a below the “R” in the COMMAND column indicates read-only operation while a “W” indicates
read/write functionality.
GROUP2
COMMAND
Values
Description
{“CFG”: {
---
---
Configuration.
“ZUIS”: “$”
R
Y/N
Common Zone installed
Y
= Yes
N
= No
“ZAIS”: “$”
R
Y/N
Zone A installed
Y
= Yes
N
= No
“ZBIS”: “$”
R
Y/N
Zone B installed
Y
= Yes
N
= No
“ZCIS”: “$”
R
Y/N
Zone C installed
Y
= Yes
N
= No
“ZDIS”: “$”
R
Y/N
Zone D installed
Y
= Yes
N
= No
“CF”: “$”
R
Y/N
Circulation fan available
Y
= Yes
N
= No
“PS”: “$”
R
Y/N
Pre-Sleep time period enabled
Y
= Yes
N
= No
“DG”: “$”
R
D,W,A
Schedule day grouping
D
= Individual
W
= Weekdays
A
= All Days
{“OOP”: {
---
---
Overall Operation
“ST”: “$”
W
F,N,Z
Operating State
F
= Off
N
= On
Z
= Fan Only
“CF”: “$”
W
Y/N
Circulation fan on
Y
= Yes
N
= No
“FL”: “##”
W
01 - 16
Fan only operation speed level (01 – 16)
{“GSO”: {
---
---
General System Operation
“OP”: “$”
W
A/M
Schedule or Manual
A
=
Schedule
M
=
Manual
“SP”: “##”
00 – 30
Set point temperature (< 8 = OFF)
“AO”: “$”
W
N,A,O
Schedule override
N
= None
A
= Advance
O
= Operation
{“GSS”: {
---
---
General System Status
“CC”: “$”
R
Y/N
Calling for cool
Y
= Yes
N
= No
“FS”: “$”
R
Y/N
Fan active
Y
= Yes
N
= No
“CP”: “$”
R
Y/N
Compressor active
Y
= Yes
N
= No
“AT”: “$”
R
W,L,R,P,S
Schedule operating mode time period
W
L
R
P
S
Wake
Leave
Return
Pre-Sleep
Sleep
“AZ”: “$”
R
W,L,R,P,S
Schedule time period advanced to
W
L
R
P
S
Wake
Leave
Return
Pre-Sleep
Sleep
{“ZUO”: {
---
---
Common Zone Operation
“UE”: “$”
R
(Y/N)
User enabled
Y
= Yes
N
= No
{“ZAO”: {
---
---
Zone A Operation
“UE”: “$”
W
(Y/N)
User enabled
Y
= Yes
N
= No
{“ZBO”: {
---
---
Zone B Operation
“UE”: “$”
W
(Y/N)
User enabled
Y
= Yes
N
= No
{“ZCO”: {
---
---
Zone C Operation
“UE”: “$”
W
(Y/N)
User enabled
Y
= Yes
N
= No
{“ZDO”: {
---
---
Zone D Operation
“UE”: “$”
W
(Y/N)
User enabled
Y
= Yes
N
= No
Continued…