52
3.9 TECHNICAL DATA
Model
REU-N2635FFC
REU-N2635WC
Unit
Appliance type
Condensing instantaneous water heater
with automatic output variation
Installation
Internal
External
G20 Nat Gas min gas pression
-0.10
mbar
G230 Air/Propane min gas pression
-0.10
mbar
G30 Butane min gas pression
-0.10
mbar
G31 Propane min gas pression
-0.10
mbar
Flue system
Forced Room Sealed
Direct Forced Exhaust
-
Temperature range with water controller
37-50, 50,55,60,65,75
°C
Tempearature range with push buttons
40,42,50,55,60,65,75,85
°C
Ignition
Direct Electronic ignition
-
Gas consumption & capacities min operation
[H
i
=Net Calorif Value; H
s
=Gross Calorific Value]
G20 Nat Gas: Input Q
m
: H
i
/ H
s
| Output P
m
4.00 / 4.40 | 4.20
4.00 / 4.40 | 4.20
kW
G20 Nat Gas flow normal operating conditions V
m
0.42
0.42
m
3
/h
G230 Air/Propane Input Q
m
: H
i
/ H
s
| Output P
m
4.00 / 4.40 | 4.20
4.00 / 4.40 | 4.20
kW
G230 Air/Propane flow normal operating conditions V
m
0.33
0.33
m
3
/h
G30 Butane: Input Q
m
: H
i
/ H
s
| Output P
m
4.60 / 5.00 | 4.80
4.60 / 5.00 | 4.80
kW
G30 Butane: flow normal operating conditions M
m
0.36
0.36
kg/h
G31 Propane: Input Q
m
: H
i
/ H
s
| Output P
m
4.00 / 4.40 | 4.20
4.00 / 4.40 | 4.20
kW
G31 Propane: flow normal operating conditions M
m
0.31
0.31
kg/h
Gas consumption & capacities nominal operation
[H
i
=Net Calorif Value; H
s
=Gross Calorific Value]
G20 Nat Gas: Input Q
n
: H
i
/ H
s
| Output P
n
42.30 / 47.00 | 45.00
42.30 / 47.00 | 45.00
kW
G20 Nat Gas flow ref. conditions V
r
4.50
4.50
m
3
/h
G230 Air/Propane: Input Q
n
: H
i
/ H
s
| Output P
n
43.20 / 47.00 | 45.00
43.20 / 47.00 | 45.00
kW
G230 Air/Propane flow ref. conditions V
r
3.50
3.50
m
3
/h
G30 Butane: Input Qn: H
i
/ H
s
| Output P
n
43.40 / 47.00 | 45.00
43.40 / 47.00 | 45.00
kW
G30 Butane: flow normal operating conditions M
n
3.40
3.40
kg/h
G31 Propane: Input Qn: H
i
/ H
s
| Output P
n
43.20 / 47.00 | 45.00
43.20 / 47.00 | 45.00
kW
G31 Propane: flow normal operating conditions M
n
3.40
3.40
kg/h
Fluegas Flowrate wet (Max. / Min. Load)
53 / 5
-
m
3
/h
Fluegas Flowrate dry (Max. / Min. Load)
46 / 4
-
m
3
/h
Flue Temp. (Max. / Min. Load)
< 70
-
°C
CO
2
conc. (Max. / Min. Load)
9.30 / 8.20
-
%
CO/CO
2
(Max. / Min. Load)
107 / 0
-
ppm
CO/CO
2
(Max. / Min. Load)
9.30 / 8.20
-
%
NO
X
(Max. / Min. Load)
38.10 / 6.70
-
ppm
Country of destination
Refer to dataplate
-
Gas category and pressure
II2H3B/P // II2H3P // II2HM3B/P
G20: 20 mbar; G230: 20 mbar
G31: 37 mbar; G30: 30 mbar
-
Type
C
13
; C
33
; C
53
; C
83P
; B
33P
A
3
-
Max water flowrate
35
35
l/min
Min operation flowrate
ON = 1.50 / OFF = 1.00
1
l/min
Min operating water pressure (P
min
)
0.10
bar
Water pressure (@nom/max flowrate - max) - (P
w
)
3 - 10
bar
Power supply
230V/50Hz
-
Electric consumption (remote/standby/antifrost)
55 / 3 / 150
55 / 3 / 154
W
Noise level (Lwa)
59
-
dB (A)
Ignition safety time TSAmax
3
sec.
Weight
28
28
kg
IP protection
IPx4D
IPx5D
-
Anti-freeze temperature protection
-20
2
-20
3
°C
NO
x
(H
s
)
27.40
27.40
mg/kWh
1
Minimum water flowrate may vary depending on the temperature setting and the inlet water temperature.
2
When NOT installled in an area of negative pressure
3
When protected from direct wind exposure.
Содержание Infinity N26e
Страница 18: ...18...
Страница 38: ...38...
Страница 47: ...47 3 6 FLOW CHART...
Страница 55: ...55...