3.4 PERFORMANCE DATA
With the control panel is possible display the performance data
of water heater.
The display shows a progressive number from 01 to 21,
alternating with the performance data. Each number
corresponds to a function, indicated in the table on the side.
To obtain Performance Data
1.
Press and hold the
(Down) button.
2.
While holding the
(Down) button for 2 seconds,
press and hold the “On/Off” button (hold both buttons
simultaneously).
3.
Use the
(Up) and
(Down) buttons to scroll to the
desired information described in the Performance Data
Table
4.
To exit performance data, repeat step 2 above.
5.
When complete, the set temperature appears in the
display.
* Refer to the Technical Data Sheet located on the inside front
cover of the water heater for additional information.
#
DATA
UNIT
01
Water Flow Data
x 0,1 l/min
02
Outgoing Temperature
°C
03
Combustion Hours
100 hours
04
Combustion Cycles
*
05
Fan Frequency
Hz
06
Additional Controllers Connected
*
07
Water Flow Control Position
0=mid;
1=open;
2=closed
08
Inlet Temperature
°C
09
Fan Current
10 mA
10
Total Bath Fill Amount
l
11
HEX Outlet Temperature
°C
12
By-Pass Flow Control Position
11=close
111=open
15
Freeze Protection Temperature
(Indoor Units Only)
°C
17
Freeze Protection Temperature
(Outdoor Units Only)
°C
19
Pump Hours
x 100 hours
20
Pump Cycles
*
21
Exhaust Temperature
°C
A0
For factory use only
A1
For factory use only
A2
For factory use only
C0
For factory use only
C1
For factory use only
C2
For factory use only