20
2.1 INSTALLATION WARNINGS
The following section contains technical information regarding the installation of the product.
For what concerns issues related to the installation (safety, environmental protection, accident
prevention, etc.) it is necessary to respect the dictates of the current legislation and the principles
of good technique. Under the current law, the systems must be held by qualified professionals.
Rinnai Infinity SENSEI Series are designed as gas continuous water heaters with temperature and flow control. The
appliance must be installed on the wall, electrically powered, connected to the gas line, to the sanitary installation and
to a suitable discharge point to drain the condensate. These systems must be adequate for the power and technical
characteristics of the product. Indoor models require the installation of a specific air intake and exhaust system for
combustion products. Outdoor models do not require the installation of any exhaust system.
Rinnai products must only be installed by qualified technical personnel, following the requirements of the UNI and
CEI standards, current legislation and local technical regulations, according to the indications of good technique. In
particular, the UNI 11528 and the CEI 64-8 and 64-9 standards must be respected.
2.1.1 APPLIANCE LOCATION
The outdoor models are designed for outdoor installation only: they must be installed in a raised position in the open
air with natural ventilation, without standing areas; where the losses of gas and combustion products are rapidly
dispersed by wind or by natural convection.
The OUTDOOR models can be installed outdoors without protection from rain, snow, etc. The
minimum ambient temperature allowed for normal operation is -20°C.
The INDOOR models can be installed in outdoor environments, partially protected: not exposed
to direct action of atmospheric precipitation. The minimum environmental temperature allowed
for normal operation is -20°C.
All pipes must be insulated with appropriate insulating materials to prevent freezing.
The appliance must be fixed to a flat vertical support wall, with the gas and water connections facing downwards.
The positioning of the flue gas exhaust terminal must comply with the regulations in force and respect the minimum
distances from the architectural elements.
The water heater must be positioned minimizing the distance of the utilities that use it most frequently to reduce
the wait for hot water from the appliance to the points of use. In applications where this distance is considerable, to
minimize the waiting times of the most distant users, it is advisable to provide a ring system and the installation of the
Rinnai recirculation kit (RCD-XHF).
It is necessary to provide an electrical plug with AC230V/50Hz and grounding power supply near the appliance,
sufficiently far from the gas, the water connections of the appliance and from the flue exhaust. For outdoor installations
it is necessary to provide a protected and waterproof outlet. The electrical cable of the appliance is 1.5m long.
The appliances must be positioned ensuring access without risk or excessive difficulty for inspection, repairs and
emergency interventions. Sufficient space for component removal and product maintenance must be guaranteed.
This product can not be used for direct heating of swimming pool water.
Both brackets (upper and lower) must be fixed to the wall using metal anchors.
Provide an adequate system for collecting and disposing of liquids in the lower part of the appliance to prevent damage
to property in the event of accidental breakage of pipes.
The air around the appliance, the exhaust and ventilation apparatus, is used for flame combustion: it must be free
of any element that may cause corrosion of the components (this includes corrosive substances, for example, in
aerosols, sprays, detergents, chemical solvents, oil-based paints, refrigerants, etc.). The appliance and its exhaust
and ventilation apparatus must not be installed in environments where corrosive, combustible or chemical substances
are present. Damage and repairs due to corrosive compounds in the air are not covered by warranty.
Installations in coastal areas may require more frequent maintenance due to corrosive phenomena of the sea air.
IMPORTANT
WARNING