23
2.5 GENERAL SCHEME AND OPERATION PRINCIPLES
Operation principles
Ignition
Press the ‘On/Off’ button on the controller to switch the appliance on; the relative led (models for external), the display
and the priority LED will light up. When a hot water tap opens, the flow sensor rotates when water passes and sends a
signal to the main control board (PCB). When the PCB detects the flow of water, it compares the temperature detected
by the hot water thermistor with the value set by the user. If necessary, the electronic ignition procedure begins by
supplying the combustion fan as the first component. Once the ventilation cycle (pre-purge) has been carried out,
t
he
combustion fan adjust air and gas inlet (Zero Governor Valve) and the burner ignited by scintillation.
Temperature control
When the flame sensor detects the combustion signal (good grounding is required), the appliance starts modulating
by controlling gas, air and the water flow rate to heat it accurately to the desired temperature (this control is carried out
from hot water thermistor).
Standby
When the taps are closed, the PCB does not receive any signal from the flow sensor and commands closing of the
gas valves, effectively extinguishing the flame to the burner. A forced ventilation cycle is then performed (post-purge).
Air
Intake Box
Combustion Fan
Check Valve
Air Intake Filter
Ignitor
Exhaust Thermistor
Gas
Water
Inlet
Indoor Type
Drain
Hot
Water
Outlet
Drain
Pressure Relief Valve
Outgoing Water Thermistor
(Twin Type)
Water Flow Control Device
Latent Heat Exchanger
Heat Exchanger
Heat Exchanger
Water Thermistor
Electrode (Grand)
Electrode
Burner
By-pass Flow Servo
Zero Governor
Noise Filter
Over Heat Switch
Orifice Unit
Venturi Unit
Flame Rod
Exhaust Duct
Water Filter and Drain
Water Flow Sensor
Inlet Water Thermistor
Exhaust
Trap
Air
Gas + Air
Heat Exchanger
Water Thermistor
Gas
Water
Inlet
Drain
Hot
Water
Outlet
Drain
Flue Outlet
Ignitor
Exhaust Thermistor
Outdoor Type
Burner
Air
Gas + Air
Pressure Relief Valve
Outgoing Water Thermistor
(Twin Type)
Water Flow Control Device
Latent Heat Exchanger
Heat Exchanger
Electrode (Grand)
Electrode
Exhaust Duct
Trap
Combustion Fan
Check Valve
By-pass Flow Servo
Zero Governor
Noise Filter
Over Heat Switch
Orifice Unit
Venturi Unit
Flame Rod
Water Filter and Drain
Water Flow Sensor
Inlet Water Thermistor
Содержание Infinity N26e
Страница 18: ...18...
Страница 38: ...38...
Страница 47: ...47 3 6 FLOW CHART...
Страница 55: ...55...