2.9 COMMISSIONING
•
Make sure the water heater is not subject to corrosive compounds in the air.
•
Check the water supply does not contain chemicals or exceeds total hardness that will damage the heat exchanger.
•
Verify the clearances from the water heater and from vent termination/air intake unit are met.
•
For indoor models: ensure you have used the correct venting products for the model installed and that you have
completely followed the venting manufacturer’s installation instructions and these installation instructions.
•
For indoor models: verify that the vent system does not exceed the maximum length.
•
Ensure that a manual gas control valve has been placed in the gas (& water) line to the water heater.
•
Before final connection of the water heater purge gas, hot water and cold water supply lines. Debris or swarf in either
the gas or water supplies may cause damage.
•
Clean the inlet water filter by closing the cold and hot water inlet isolation (shut-off) valves. Put a bucket under the
filter at the bottom of the water heater to catch any water that is contained inside the unit. Unscrew the water filter.
Rinse the filter to remove any debris. Install the filter and open the isolation valves.
•
Turn on gas and cold water supplies and test for water leaks and gas escapes near the unit.
•
Ensure that hot and cold water lines are not crossed to the unit and are leak free.
IMPORTANT
Remove front panel and confirm the control board dipswitch settings are set to the correct
positions as required:
•
factory default;
•
sideways flue diverter fitted (only outdoor models);
•
correct flue system extension (only indoor models);
•
high altitude.
Fix the front panel back.
•
Isolate gas supply. Remove test point screw located on the gas inlet connection and attach pressure gauge.
•
Turn the power ‘on’ at the power point socket and turn on gas.
•
If controllers are fitted, ensure they are ‘ON’, with the maximum delivery temperature selected and open all available
hot water outlets.
•
If controllers are not fitted, simply open all available hot water outlets.
CAUTION
Ensure building occupants do not
have access to hot water outlets during this procedure.
•
Operate all other gas appliances connected to the same gas line (boiler, cook top, etc..) at their maximum gas rate.
•
With all gas appliances in operation at maximum gas rate, the pressure should read between 20mbar on natural
gas. On lPG the pressure should be 30mbar/37mbar propane. If the pressure is lower, the gas supply is inadequate
and the appliance will not operate to specification. It is the Installers responsibility to check the gas meter, service
regulator and pipe work for correct operation/sizing and rectify as required
.
WARNING
The gas regulator on the appliance is electronically controlled and factory pre-set: it does not need
any adjustment during installation.
Prior to making any changes, contact Rinnai.
•
Close the hot water taps including the shower.
•
Inspect and clean the strainer located on the cold water inlet connection. This procedure may need to be repeated
to ensure the strainer remains clear, especially on new installations.
•
If remote controllers are fitted, it is necessary to test their operation through the complete range of functions.
•
Confirm the hot water delivery temperature using a thermometer.
•
If ‘Sub’ controllers are fitted, ensure temperatures exceeding 50°C cannot be selected.
•
After testing is completed, explain to the householder the functions and operation of the water heater and the
controllers.
•
Remind the customer to complete the warranty card and forward it to Rinnai.
•
Inform customer on use of an adequate water softening system to prevent damages to heat exchanger.
•
leave the manual to customer.
•
If the water heater is not needed for immediate use, then drain the water from the heat exchanger.