1.3 OPERATION
The Rinnai water heater is able to supply hot water at a constant temperature, making sudden changes that result
from the simultaneous use of several users or from variations in the temperature of the cold water used to feed the
appliance (pre-heated water from solar panels, etc).
To maximize these benefits, increasing comfort and reducing consumption, Rinnai recommends setting the appliance
to the minimum temperature most suitable for the intended use and using hot water without mixing with cold.
The Rinnai instanteous water heaters do not have a ‘pilot flame’. The opening
of any tap will immediately activate the electronic ignition: as soon as the
water flows through the appliance, the burner is turned on by an electronic
system; when the tap is closed and the water flow stops, the appliance
completely switches off the burner flame.
Inside the appliance, the water temperature is monitored by several
integrated sensors: when the hot water temperature exceeds 3°C the set
value, the ‘In Use’ indicator on the control switches off. This means that
the appliance burner is switched off and that the water is no longer heated
until the temperature has dropped below this value.
All Rinnai water heaters are equipped with a control panel for general
appliance control, hot water temperature selection and diagnostic functions.
The control panel allows you to have full control over the appliance and to
adapt it in a simple and immediate way to the use of hot water according to
your needs.
In the indoor models, the control panel is integrated on the front panel of the appliance and cannot be removed; in
the outdoor models, the control panel is available as a remote control to be connected to the appliance by means of a
cable that can be remotely installed in a domestic environment.
The outdoor models can operate without connecting the remote control: the operation of the appliance remains the
same as described previously, but the water heater works at a fixed temperature and it is not possible to change the
value to adapt it to different needs.
To be able to control the device from different environments, more conveniently, you can add three additional remote
commands to the initial configuration, for a maximum of four control panels. Additional remote controls are optional
accessories. However, only one control panel can be set as ‘Master’ (or main): normally this is the one placed in the
kitchen is selected. The additional control panels are automatically designated as ‘Sub’ (or secondary) commands and
are usually installed in environments such as the bathroom, the laundry, etc.
The maximum temperature available for secondary controls is always limited to 50°C from the system: this is to ensure
maximum comfort of use and above all to prevent the risk of burns during use in the environments in which they are
installed.
All control panels are individually programmable, although the appliance only heats the water at one temperature at
a time.
Outdoor model
Outdoor model
Indoor model
Indoor model
Control panel
Control panel
Standard remote
controller (MC-601)
Standard remote
controller (MC-601)
OPEN
ON
Cold
Hot
CLOSED
OFF
Cold