Evolve 950 Installation Guide: 12471-A 01-14
|
9
Clearances
(from the edge of the glass)
The appliance must not be installed where curtains or other combustible materials could
come into contact with the heater. In some case curtains may need restraining. The
clearances listed below are minimum clearances unless otherwise stated.
Floor protection
Heat radiating from this fire may
over time affect the appearance
of some materials used for
flooring, such as, carpet, vinyl,
cork or timber. This may be
amplified if the air contains
cooking vapours or cigarette
smoke. To avoid this occurring,
it is recommended that a mat be
placed in front of this appliance.
Mantels and surrounds
A mantel and surround are
allowed providing they are
outside the minimum clearances
shown.
Hearths
A hearth is not necessary but
can be used for decorative
purposes or protection of
sensitive flooring if required.
A hearth must not obscure the
front of the fire.
400
400
1000
1000
To ceiling
400
Note:
Measurements are taken from the edge of the glass.
The 400 mm side clearance includes side walls.
C - Surround from side of glass
B - Mantel depth
A - Mantel height from top of glass
D - Surround
projection
A
Mantel height from top of glass
400 mm min.
B
Mantel depth at A - 400 mm (vertical clearance)
250 mm max.
For every 50 mm of added mantel depth, there must be an additional 100 mm of
vertical clearance. For example; a mantel depth (B) of 350 mm will require 600
mm (A) of vertical clearance.
C
Surround from side of glass
250 mm min.
D
Surround projection at C - 250 mm (side clearance)
250 mm max.