Specification

Evolve 950

Specification summary

Input 

 

= 10-34 MJ/h

Output   

= 2.4-8.13* kW

Efficiency 

= 86% (on high)

Heating area 

= 82-125 m

2

**

Gas type  

= NG or ULPG

Inbuilt exhaust balance flued 

convection flame fire with electronic 

temperature control, timer and 

remote.

Suitability

Ideal for living rooms and open plan 

areas. Versatile power flue system 

makes for easy installation in almost 

any living space, including bedrooms.

The Evolve is ideal for a new build 

installation into a false (mock) 

chimney.

Data plate

Located inside the appliance, upper 

right hand side.

 

Convection fan

2-speed centrifugal, double diameter 

160 x 180 mm.

Gas connection

½ “ BSP, the gas supply terminates 

inside the heater—lower left hand 

side of the appliance.

Ignition

Continuous spark electronic ignition.

Installation considerations

Room size—smaller rooms will heat 

up quickly, and due to the efficiency 

of the appliance, the heater (if auto 

off is selected) will turn to a low flame 

setting once the set temperature has 

been reached.

Noise level - 

37-45 dB(A)

Power flue

Inner 50 mm, outer 70~80 mm. 

Appliance must be installed with a 

Rinnai flue system.

Power consumption and electrical 

supply

High 

= 160 W

Standby  = <8 W

This heater has a 1.5 m power cord 

with a three pin plug supplied. The 

power cord passes through a slot in 

the back right hand corner of the 

appliance.

Safety devices

Flame failure sensing system, 

pressure relief, overheat safety 

switch, air temperature sensor, 

thermal fuse, overcurrent fuse, and 

spark detector.

Temperature control

Thermostatic, temperature control 
range 16-26 °C.

Weight

 - 75 kg

* Will vary according to gas type and flue configuration    ** Will vary depending on geographical location in NZ

Dimensions are in mm.

 1070 

 660 

 430 

 65 

 500 ±25

 420 

 960 

 560

 568 

 25 

 25 

Содержание Evolve 950

Страница 1: ...Evolve 950 Installation guide Models RHFE950ETRN RHFE950ETRL...

Страница 2: ...by authorised personnel Warning Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life For more information about buying using an...

Страница 3: ...nstallation 10 Flueing options 11 Evolve 950 installation overview 12 Connect flue system 13 Install heater into enclosure 14 Removing and replacing the glass panel 15 Install burn media log set 16 In...

Страница 4: ...These instructions are to be used in conjunction with the Rinnai Arriva and Evolve flue installation guide supplied with the flue kits Carton contents The components for the Evolve 950 are supplied i...

Страница 5: ...k electronic ignition Installation considerations Room size smaller rooms will heat up quickly and due to the efficiency of the appliance the heater if auto off is selected will turn to a low flame se...

Страница 6: ...t to malfunction 175 mm 175 mm F r o n t o f e n c l o s u r e Consumer pipe Adapter supplied R e a r o f e n c l o s u r e Gas supply pressure to be 1 13 to 3 kPa Flexible pipe supplied 175 197 Where...

Страница 7: ...lation The penetration for the flue transition only needs to be made for direct flue installations where the terminal is directly to the rear of the appliance If no flue pipe penetration is required t...

Страница 8: ...s such as wood or plaster The heater must be positioned within the enclosure on a flat level surface that allows free movement of the appliance The joists used to support the appliance off the ground...

Страница 9: ...tel and surround are allowed providing they are outside the minimum clearances shown Hearths A hearth is not necessary but can be used for decorative purposes or protection of sensitive flooring if re...

Страница 10: ...clearance required to to a mantel The image adjacent shows the dimension from the edge of the frame in the case of the Evolve the 400 mm dimension can be taken from the edge of the glass For a TV moun...

Страница 11: ...two 45 bends ESBEND False wall A B A flue components Direct flue ASPDFK Coaxial pipe ESPIPE900 Bend 1 x 90 ESBEND x 1 Condensate trap ESCONDK Roof cowl ESROOFCOWL A flue configuration could have a fl...

Страница 12: ...so be completed at this point 4 Connect flue system 5 Install heater into enclosure screw to frame and complete gas air hose and flue connection p 14 6 Install burn media refer p 16 19 8 Install outer...

Страница 13: ...eady connected to the flue It is much easier to connect the air hose to the unit than to connect the air hose to the flue once the heater is in place Ensure the air intake hose of the heater is proper...

Страница 14: ...the telescopic extension tube and secure together with the pipe clamp 3 Secure the heater flange in place using the 11 seismic constraint screws provided 4 Complete gas air hose and flue connection If...

Страница 15: ...two at the top and two at the bottom When replacing tighten all four screws and then back off by quarter of a turn If the glass panel is screwed too tight the panel will bow and the spring release mec...

Страница 16: ...ing pins at the back of the burner the log will sit up against the back of the combustion chamber 2 Back right log Align bottom locating holes with the locating pins at the back of the burner the log...

Страница 17: ...left hand operational area highlighted and DO NOT have them touching the flame rod as this will cause a blockage and the unit will not start Place the granules evenly do not stack around the logs in t...

Страница 18: ...t covered by warranty The unit must never be used with broken stones or other burn media except those specifically designed for the Evolve 1G 2G 3W 4G 5W L1 L2 L3 L4 L5 L6 w w w w w w w w 1 Place firs...

Страница 19: ...ket 6 Place back three large grey stones Place the three large grey stones L1 L2 L5 at the back of the burner as shown they can be positioned over the locating pins w w w w w g g g g g g 9 Place small...

Страница 20: ...tructions to complete the gas pressure adjustments When commissioning is complete check for full and correct operation of the appliance and return the commissioning sheet to its plastic pouch Commissi...

Страница 21: ...screws Tabs on inner frame Lip of combsution chamber glass Magnets Installing the optional mesh guard The optional mesh guard if purchased needs to be installed before the inner frame as the inner fr...

Страница 22: ...ll from the appliance Continued difficulty or delay in establishing a flame Flame appears either very short or very long Flame only burns part way across the burner Severe soot building up on the insi...

Страница 23: ...TR FM BL AC 230 240V bl bl r 3 2 1 3 2 1 4 3 2 1 9 8 7 6 5 4 3 2 1 r bk w gy or bl bl r w w bk bk 3 1 4 3 2 1 gr y 1 2 3 4 3 4 1 2 2 1 1 2 1 2 1 2 1 1 3 3 w bk r w bk r bl 1 1 4 4 w bk r bl COM HI MED...

Страница 24: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz Evolve 950 Installation Guide 12471 A 01 14...

Отзывы: